A kinematic model for calculating cup alignment error during total hip arthroplasty.
نویسندگان
چکیده
Reduced range of motion, prosthetic impingement, and joint dislocation can all result from misalignment of the acetabular component (i.e. cup alignment) in patients undergoing total hip arthroplasty. Most methods for acetabular component alignment are designed to provide 45-50 degrees abduction and 15-25 degrees of operative anteversion (also known as flexion) with respect to the anterior pelvic plane coordinate system. Yet in most cases, this coordinate system is not assigned properly, due to differences in patient anatomy and improper positioning in the operating room. This misalignment can result in an error in the cup alignment, which can cause the above-mentioned consequences. This work presents a complete mathematical formulation for the analysis of the inaccuracies related to the anterior pelvic plane axes (APPA) definition and their effect on final cup orientation. We do this by introducing a method taken from Kinematics of Mechanisms, and by representing the errors in the APPA as three concurrent axes of rotation, followed by the version and abduction rotations which are defined relative to the previous rotations. We also present a sensitivity analysis of the results by introducing differential changes between sequential coordinate frames, which simulates the errors in the APPA and their effect on cup orientation. Finally, we demonstrate a computational method which provides corrected version and abduction angles to achieve the desired cup orientation, given that the actual measurement errors are known.
منابع مشابه
Combined anteversion of the total hip arthroplasty implanted with image-free cup navigation and without stem navigation
In total hip arthroplasty (THA), combined anteversion (CA), the sum of cup anteversion (AV) and stem antetorsion (AT) are used as parameters to assess the appropriateness of overall prosthetic alignment. In this study, we evaluated the CA value based on the post-operative computed tomography (CT) measurements in our patient population who underwent THA using the OrthoPilot™ image-free navigatio...
متن کاملA challenge on Orthopedic Sciences: The Influence of Spinal Disease and Deformities on Total Hip Arthroplasty: A Review on Literature
Background: Adult degenerative disorders of hip and spine are common. The recent studies inconsistently havediscussed about the influence of spinal disorders on total hip arthroplasty (THA). In this review, we discussed clearlyabout these relationships and their effects on the most appropriate position of the acetabular component.Methods: We searched on databases and evaluated the articles abou...
متن کاملAccuracy of Combined Anteversion in the Combined Anteversion Technique with Image-free Navigated Total Hip Arthroplasty
In recent literatures dealing with optimization of prosthetic alignment in total hip arthroplasty (THA), the concept of combined anteversion (CA), which is the sum of acetabular anteversion (AV) and femoral antetorsion (AT), has been addressed. Widmer attempted to determine the optimal CA using a computer simulation study . He proposed the “new safe zone” for the CA value to achieve essential r...
متن کاملThree-Dimensional Templating for Acetabular Component Alignment During Total Hip Arthroplasty.
Appropriate placement of the acetabular cup is an important determinant of implant stability and longevity. Malposition of acetabular cups negatively influences prosthesis survival and leads to an increased dislocation rate. The objective of the study was to determine the role of 3-dimensional templating in obtaining accurate acetabular component placement in total hip arthroplasty. In this com...
متن کاملIntellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty
Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanics
دوره 38 11 شماره
صفحات -
تاریخ انتشار 2005