Magnetic Resonance Imaging–Derived Renal Oxygenation and Perfusion During Continuous, Steady‐State Angiotensin‐II Infusion in Healthy Humans

نویسندگان

  • René van der Bel
  • Bram F. Coolen
  • Aart J. Nederveen
  • Wouter V. Potters
  • Hein J. Verberne
  • Liffert Vogt
  • Erik S. G. Stroes
  • C. T. Paul Krediet
چکیده

BACKGROUND The role of kidney hypoxia is considered pivotal in the progression of chronic kidney disease. A widely used method to assess kidney oxygenation is blood oxygen level dependent (BOLD)-magnetic resonance imaging (MRI), but its interpretation remains problematic. The BOLD-MRI signal is the result of kidney oxygen consumption (a proxy of glomerular filtration) and supply (ie, glomerular perfusion). Therefore, we hypothesized that with pharmacological modulation of kidney blood flow, renal oxygenation, as assessed by BOLD-MRI, correlates to filtration fraction (ie, glomerular filtration rate/effective renal plasma flow) in healthy humans. METHODS AND RESULTS Eight healthy volunteers were subjected to continuous angiotensin-II infusion at 0.3, 0.9, and 3.0 ng/kg per minute. At each dose, renal oxygenation and blood flow were assessed using BOLD and phase-contrast MRI. Subsequently, "gold standard" glomerular filtration rate/effective renal plasma flow measurements were performed under the same conditions. Renal plasma flow decreased dose dependently from 660±146 to 467±103 mL/min per 1.73 m(2) (F[3, 21]=33.3, P<0.001). Glomerular filtration rate decreased from 121±23 to 110±18 mL/min per 1.73 m(2) (F[1.8, 2.4]=6.4, P=0.013). Cortical transverse relaxation rate (R2*; increases in R2* represent decreases in oxygenation) increased by 7.2±3.8% (F[3, 21]=7.37, P=0.001); medullar R2* did not change. Cortical R2* related to filtration fraction (R(2) 0.46, P<0.001). CONCLUSIONS By direct comparison between "gold standard" kidney function measurements and BOLD MRI, we showed that cortical oxygenation measured by BOLD MRI relates poorly to glomerular filtration rate but is associated with filtration fraction. For future studies, there may be a need to include renal plasma flow measurements when employing renal BOLD-MRI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angiotensin II decreases the renal MRI blood oxygenation level-dependent signal.

Acute experimental reduction of renal blood flow decreases the renal blood oxygenation level-dependent (BOLD) MRI signal in animals. Angiotensin II also reduces renal blood flow, but the ability of BOLD MRI to dynamically detect this response has not yet been investigated in humans. Six healthy male volunteers underwent an individual dose-finding study to identify the intravenous doses of angio...

متن کامل

The effects of Mas receptor antagonist (A779) and renal perfusion pressure on serum nitrite concentration in male and female rats when angiotensin II receptors 1 & 2 were blocked

Introduction: Renin angiotensin system has an important role in blood pressure and renal functions. Active angiotensin-converting enzyme 2 converts angiotensin I into angiotensin-(1-7) which is a vasodilator hormone and interacts with nitric oxide changes as well as other angiotensin II receptors. In this study we evaluated the role of Mas receptor antagonist (A779) and renal perfusion press...

متن کامل

Modulation of renal oxygenation and perfusion in rat kidney monitored by quantitative diffusion and blood oxygen level dependent magnetic resonance imaging on a clinical 1.5T platform

BACKGROUND To investigate the combined use of intravoxel incoherent motion (IVIM) diffusion-weighted (DW) and blood oxygen level dependent (BOLD) magnetic resonance imaging (MRI) to assess rat renal function using a 1.5T clinical platform. METHODS Multiple b-value DW and BOLD MR images were acquired from adult rats using a parallel clinical coil arrangement, enabling quantitation of the appar...

متن کامل

Assessment of segmental myocardial blood flow and myocardial perfusion reserve by adenosine-stress myocardial arterial spin labeling perfusion imaging.

PURPOSE To determine the feasibility of measuring increases in myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) on a per-segment basis using arterial spin labeled (ASL) magnetic resonance imaging (MRI) with adenosine vasodilator stress in normal human myocardium. MATERIALS AND METHODS Myocardial ASL scans at rest and during adenosine infusion were incorporated into a routine...

متن کامل

Angiotensin receptor blockade has protective effects on the post-stenotic porcine kidney

Angiotensin-converting enzyme inhibitors/angiotensin II receptor blockers (ARBs) may induce an acute decrease of glomerular filtration rate (GFR) in the stenotic kidney in renal artery stenosis, but most patients tolerate these drugs well. We hypothesized that angiotensin-converting enzyme inhibitors/ARBs stabilize stenotic kidney function during prolonged treatment by conferring protective eff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016