Early clinical results of the telemetric adjustable pulmonary artery banding FloWatch-PAB.

نویسندگان

  • Damien Bonnet
  • Antonio F Corno
  • Daniel Sidi
  • Nicole Sekarski
  • Maurice Beghetti
  • Ingram Schulze-Neick
  • Margrit Fasnacht
  • Emmanuel Le Bret
  • Afksendyios Kalangos
  • Pascal R Vouhé
  • Ludwig K von Segesser
چکیده

BACKGROUND Adjustment of pulmonary artery banding (PAB) may be a challenging procedure in complex congenital heart defects. Whatever the technique used, subsequent re-operations are frequently needed to control the pulmonary blood flow or pressures. OBJECTIVE To report the efficacy of a new telemetric adjustable PAB (FloWatch-PAB) operated with the help of an external control unit that transmits to the implant energy and commands to further narrow or release the pulmonary artery using radiofrequency waves. METHODS AND RESULTS In a multicenter, prospective, nonrandomized, single-arm clinical investigation, 13 children (median age, 4.5 months; range, 6 days to 11 years; median weight, 4.2 kg; range, 3.1 to 27 kg) underwent implantation of the FloWatch-PAB through median sternotomy in 8 and left thoracotomy in 5. The diagnosis was multiple ventricular septal (VSD) defects with complex anatomy in 3, single ventricle without pulmonary stenosis in 2, VSD with elevated pulmonary vascular resistance (PVR) in 2, atrio-ventricular canal (AVC) with elevated pulmonary vascular resistance in 1, AVC with diminutive right ventricle in 1, complex transposition of the great arteries in 3, and pulmonary atresia with complex pulmonary arteries anatomy in 1. All patients had normosystemic systolic pulmonary artery pressure. Additional procedures were performed in 7: atrial septectomy in 2, double aortic arch division in 1, patent ductus arteriosus ligation in 2, and coarctation repair in 2. There were no early or late deaths or device-related complications in a mean follow-up of 24 weeks (range, 18 to 42 weeks). A mean of 5.8 telemetric regulations per patient using the FloWatch-PAB were required to adjust the tightening of the PAB to the clinical needs (narrowing 74%, releasing 26%). At last follow-up, systolic pulmonary artery pressure was within normal range in all patients but 1. Systemic oxygen saturation demonstrated optimal regulation of the pulmonary blood flow in all according to each specific defect. Four patients were successfully corrected (VSD closure, AVSD repair, and 2 arterial switches with VSD closure). The device was easily removed and the pulmonary artery re-expanded spontaneously. CONCLUSIONS This new device is safe and allows optimal adjustment of PAB in complex heart defects. In children requiring PAB, the use of this technology can obviate the need for early re-operations and appears to be a valuable option in the panel of surgical alternatives for selected infants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Telemetrically adjustable pulmonary artery banding: first application in Greece.

We describe the first application in Greece of a telemetrically adjustable device for pulmonary artery banding (FloWatch-PAB device) in a 2-month-old baby, weighing 3.6 kg, with congenital heart disease (complete atrioventricular septal defect with pulmonary hypertension). The surgical application of the device was easy, the postoperative course of the patient was smooth, and the telemetric reg...

متن کامل

Multiple Ventricular Septal Defects: A New Strategy

INTRODUCTION A multicenter prospective study was conducted to evaluate a new strategy for multiple Ventricular Septal Defects (VSDs). MATERIALS AND METHODS From 2004 to 2012 17 consecutive children (3 premature, 14 infants), mean age 3.2 months (9 days-9 months), mean body weight 4.2 kg (3.1-6.1 kg), with multiple VSDs underwent Pulmonary Artery Banding (PAB) with an adjustable FloWatch-PAB(®...

متن کامل

Doppler-guided regulation of a telemetrically operated adjustable pulmonary banding system.

OBJECTIVES We report on the Doppler-assessed regulation of an adjustable pulmonary artery band (PAB) in an animal model and in our first group of patients. BACKGROUND Indications for pulmonary artery banding have expanded to include patients requiring a late arterial switch. A telemetry-operated, fully implantable, adjustable PAB system (FloWatch- PAB, Endoart SA, Lausanne, Switzerland) has b...

متن کامل

Pulmonary Artery Banding is Still a Valuable Option

In this work, Corno (1) presents long-term outcomes in a small group of patients with multiple ventricular septal defects treated with adjustable pulmonary artery banding (PAB). The results were satisfactory, with few complications. Despite recent progress in pediatric cardiac surgery, surgical management of very small babies with true Swiss cheese septum and cardiac failure is still challengin...

متن کامل

Indications, Results and Mortality of Pulmonary Artery Banding Procedure: a Brief Review and Five- year Experiences

Background Pulmonary artery banding (PAB) is a technique of palliative surgical therapy used by congenital heart surgeons as a staged approach to operative correction of congenital heart defects. Materials and Methods We report 5- year experiences from January 2011 to January 2016 of Imam Reza Hospital center (a tertiary referral hospital in Mashhad city, North East of Iran) that consist of 50 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 110 11 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2004