Multi-source information fusion based fault diagnosis of ground-source heat pump using Bayesian network

نویسندگان

  • Baoping Cai
  • Yonghong Liu
  • Qian Fan
  • Yunwei Zhang
  • Zengkai Liu
  • Shilin Yu
  • Renjie Ji
چکیده

In order to increase the diagnostic accuracy of ground-source heat pump (GSHP) system, especially for multiple-simultaneous faults, the paper proposes a multi-source information fusion based fault diagnosis methodology by using Bayesian network, due to the fact that it is considered to be one of the most useful models in the filed of probabilistic knowledge representation and reasoning, and can deal with the uncertainty problem of fault diagnosis well. The Bayesian networks based on sensor data and observed information of human being are established, respectively. Each Bayesian network consists of two layers: fault layer and fault symptom layer. The Bayesian network structure is established according to the cause and effect sequence of faults and symptoms, and the parameters are studied by using Noisy-OR and NoisyMAXmodel. The entire fault diagnosis model is established by combining the two proposed Bayesian networks. Six fault diagnosis cases of GSHP system are studied, and the results show that the fault diagnosis model using evidences from only sensor data is accurate for single fault, while it is not accurate enough for multiple-simultaneous faults. By adding the observed information as evidences, the probability of fault present for single fault of ‘‘Refrigerant overcharge’’ increases to 100% from 99.69%, and the probabilities of fault present for multiple-simultaneous faults of ‘‘Non-condensable gas’’ and ‘‘Expansion valve port largen’’ increases to almost 100% from 61.1% and 52.3%, respectively. In addition, the observed information can correct the wrong fault diagnostic results, such as ‘‘Evaporator fouling’’. Therefore, the multi-source information fusion based fault diagnosis model using Bayesian network can increase the fault diagnostic accuracy greatly. 2013 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Fault Diagnosis Methodology for Gear Pump Based on EEMD and Bayesian Network

This paper proposes a fault diagnosis methodology for a gear pump based on the ensemble empirical mode decomposition (EEMD) method and the Bayesian network. Essentially, the presented scheme is a multi-source information fusion based methodology. Compared with the conventional fault diagnosis with only EEMD, the proposed method is able to take advantage of all useful information besides sensor ...

متن کامل

Research on Transformer Fault Diagnosis based on Multi-source Information Fusion

DGA (Dissolved Gas Analysis) is the traditional transformer fault diagnosis method, but it mainly depends on the experience of operators. In order to solve the limitations of traditional method, this paper introduces intelligent method for fault diagnosis of transformer. The intelligent method made fusion of various data, including SCADA data, oil dissolved gas sensor data, related electrical t...

متن کامل

Determining the optimal size of a ground source heat pump within an air-conditioning system with economic and emission considerations

One of the most challenging issues in modern-day building energy management involves equipping the buildings with more energy efficient facilities. In this paper, a hybrid system for cooling/heating for a residential building is developed and optimized. The system consists of a ground source heat pump (GSHP) as well as an electric chiller (EC) and boiler. The model is implemented in MATLAB ...

متن کامل

Large Power Transformer Fault Diagnosis and Prognostic Based on DBNC and D-S Evidence Theory

Power transformer is a core equipment of power system, which undertakes the important functions of power transmission and transformation, and its safe and stable operation has great significance to the normal operation of the whole power system. Due to the complex structure of the transformer, the use of single information for condition-based maintenance (CBM) has certain limitations, with the ...

متن کامل

Assessment and Deployment of Ground Source Heat Pump for Air Pollution Reduction in Tehran, Iran

The use of renewable energies, especially in metropolises has led to a reduction in environmental pollution and greater access to clean, renewable and sustainable energy. This paper evaluates the effectiveness of a national plan adopted by the Tehran city council for reducing air pollutions. This plan is designed to increase the share of renewable energies in residential buildings. This study a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015