Multinozzle emitter array chips for small-volume proteomics.

نویسندگان

  • Pan Mao
  • Rafael Gomez-Sjoberg
  • Daojing Wang
چکیده

High-throughput multiplexed proteomics of small-volume biospecimens will generate new opportunities in theranostics. Achieving parallel top-down and bottom-up mass spectrometry analyses of target proteins using a unified apparatus will improve proteome characterization. We have developed a novel silicon-based microfluidic device, multinozzle emitter array chip (MEA chip), as a new platform for small-volume proteomics using liquid chromatography-nanoelectrospray ionization mass spectrometry (LC-nanoESI-MS). We demonstrate parallel, on-chip, and online LC-MS analysis of hemoglobin and its tryptic digests directly from microliters of blood, achieving a detection limit of less than 5 red blood cells. Our MEA chip will enable clinical proteomics of small-volume samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multinozzle emitter arrays for nanoelectrospray mass spectrometry.

Mass spectrometry (MS) is the enabling technology for proteomics and metabolomics. However, dramatic improvements in both sensitivity and throughput are still required to achieve routine MS-based single cell proteomics and metabolomics. Here, we report the silicon-based monolithic multinozzle emitter array (MEA) and demonstrate its proof-of-principle applications in high-sensitivity and high-th...

متن کامل

Microfabricated monolithic multinozzle emitters for nanoelectrospray mass spectrometry.

Mass spectrometry is the enabling technology for proteomics. To fully realize the enormous potential of lab-on-a-chip in proteomics, a major advance in interfacing microfluidics with mass spectrometry is needed. Here, we report the first demonstration of monolithic integration of multinozzle electrospray emitters with a microfluidic channel via a novel silicon microfabrication process. These mi...

متن کامل

Top-Down Proteomics of a Drop of Blood for Diabetes Monitoring

The most common markers for monitoring patients with diabetes are glucose and HbA1c, but additional markers such as glycated human serum albumin (HSA) have been identified that could address the glycation gap and bridge the time scales of glycemia between transient and 2-3 months. However, there is currently no technical platform that could measure these markers concurrently in a cost-effective...

متن کامل

Fourier transform ion mobility spectrometry with multinozzle emitter array electrospray ionization

Fourier transform ionmobility spectrometry (FT-IMS) is a useful multiplexingmethod for improving the duty cycle (DC) of IMS from 1 to 25% when using an entrance and exit ion gate to modulate the ion current with a synchronized square wave chirp. To improve sensitivity further, this paper investigated the performance of FT-IMS using a frequency modulated single gate IMS system coupled to multi e...

متن کامل

Measurement of transverse emittance and coherence of double-gate field emitter array cathodes

Achieving small transverse beam emittance is important for high brightness cathodes for free electron lasers and electron diffraction and imaging experiments. Double-gate field emitter arrays with on-chip focussing electrode, operating with electrical switching or near infrared laser excitation, have been studied as cathodes that are competitive with photocathodes excited by ultraviolet lasers,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 85 2  شماره 

صفحات  -

تاریخ انتشار 2013