Impact and Flexural Strength, and Fracture Morphology of Acrylic Resins With Impact Modifiers

نویسندگان

  • Fernanda Faot
  • Leonardo H V Panza
  • Renata C M Rodrigues Garcia
  • Altair Antoninha Del Bel Cury
چکیده

OBJECTIVES This study evaluated the impact and flexural strength and analyzed the fracture behavior of acrylic resins. METHODS Eighteen rectangular specimens were fabricated of Lucitone 550, QC 20 (both unreinforced acrylic resins), Impact 1500 (extra strength impact), Impact 2000 (high impact) according to the manufacturers' instructions. The impact strength was evaluated in notched specimens (50x6x4mm) and flexural strength in unotched (64x10x3.3mm), using three-point bending test, as well as, stress at yield, Young modulus and displacement at yield. Fragments from mechanical tests were observed by SEM. Data from impact strength, stress at yield and displacement at yield were analyzed by 1-way ANOVA and Tukey test (alpha=0.05). Young modulus values were analyzed by One-way ANOVA and Dunnett T3 multiple comparisons test (alpha=0.05). RESULTS Mean values of impact strength and stress at yield values were higher (P<.005) for Impact 2000 while Young modulus was higher (P<.05) for Lucitone 550; Impact 1500 and Impact 2000 showed significant values (P<.05) in the displacement at yield. Impact fractures of the all acrylic resins were brittle. Bending fractures of Lucitone 550 and Impact 2000 were brittle, QC 20 fractures were ductile and Impact 1500 showed brittle (75%) and ductile (25%) fractures. CONCLUSION Within the limitations of this study, the Impact 2000 showed improved mechanical properties with high capacity of stress absorption and energy dissipation before the fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elastic modulus and flexural strength comparisons of high-impact and traditional denture base acrylic resins.

BACKGROUND Fractures of acrylic resin dentures are a common occurrence in clinical dentistry. The denture may be fractured accidentally when dropped or while in service in the mouth due to flexural fatigue. OBJECTIVES The aim of this study was to compare the elastic modulus and the flexural strength between two heat-cured acrylic resins used in denture bases: a high-impact resin (Lucitone 199...

متن کامل

A comparison of the impact strength between Acropars and Meliodent acrylic resins

A comparison of the impact strength between Acropars and Meliodent acrylic resins Dr. F. Golbidi* - Dr. A. Meghdadi** *-Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry – Isfahan University of Medical Sciences. **-Dentist. Background and Aim: One of the mostly used materials in removable prostheses are acrylic resins with various physical and mechanical properties. The impact ...

متن کامل

Addition of glass fibers and titanium dioxide nanoparticles to the acrylic resin denture base material: comparative study with the conventional and high impact types.

PURPOSE The aim of this study was to clarify the effect of addition of glass fibers and titanium dioxide nanoparticles to the conventional acrylic resin. The tested parameters were monomer release, deflection at fracture, flexural strength, flexural modulus, and toughness. The modified acrylic resin groups were compared to the conventional unmodified and high impact types. The correlation betwe...

متن کامل

Comparison of Impact Strength and Fracture Morphology of Different Heat Cure Denture Acrylic Resins: An In vitro Study

BACKGROUND The fracture of acrylic resin denture is rather common occurrence and causes inconvenience to the patients. This study was carried out to evaluate and compare the impact strength and fracture morphology of four different heat cure acrylic materials. MATERIALS AND METHODS Acrylic resin specimens were prepared using preformed metal die of dimension 65 × 10 × 3 mm. The specimens were ...

متن کامل

Comparative study of flexural strength of four acrylic resins before and after thermocycling process

Objectives Acrylic resins are one of the most important denture base materials in dentistry due to their favourable mechanical and physical properties. The purpose of present study is to compare 4 available acrylic flexural strength properties before and after thermocycling. Methods Acrylic resin specimens of Meliodent (Heraeus Kulzer, Hanau, Germany), Vertex (Vertex-dental BV, Zeist, Netherla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009