Saturation effect in functional photoacoustic imaging.

نویسندگان

  • Jing Wang
  • Tan Liu
  • Shuliang Jiao
  • Ruimin Chen
  • Qifa Zhou
  • K Kirk Shung
  • Lihong V Wang
  • Hao F Zhang
چکیده

We investigate the saturation effect, which describes the violation of the linearity between the measured photoacoustic amplitude and the object's optical absorption coefficient in functional photoacoustic imaging when the optical absorption in the object increases. We model the optical energy deposition and photoacoustic signal generation and detection in a semi-infinite optical absorbing object. Experiments are carried out by measuring photoacoustic signals generated from an ink-filled plastic tube. The saturation effect is studied by varying the optical absorption coefficient in the model and the ink concentration in the photoacoustic experiments. By changing the center frequency of the ultrasonic detector, the requirement to minimize the saturation effect in functional photoacoustic imaging is established.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

aturation effect in functional photoacoustic imaging

ao F. Zhang niversity of Wisconsin-Milwaukee epartment of Electrical Engineering and Computer Science 200 N Cramer Street ilwaukee, Wisconsin 53201 Abstract. We investigate the saturation effect, which describes the violation of the linearity between the measured photoacoustic amplitude and the object’s optical absorption coefficient in functional photoacoustic imaging when the optical absorpti...

متن کامل

Single-wavelength functional photoacoustic microscopy in biological tissue.

Recently, we developed a reflection-mode relaxation photoacoustic microscope, based on saturation intensity, to measure picosecond relaxation times using a nanosecond laser. Here, using the different relaxation times of oxygenated and deoxygenated hemoglobin molecules, both possessing extremely low fluorescence quantum yields, the oxygen saturation was quantified in vivo with single-wavelength ...

متن کامل

Imaging brain hemodynamic changes during rat forepaw electrical stimulation using functional photoacoustic microscopy

The present study reported the development of a novel functional photoacoustic microscopy (fPAM) system for investigating hemodynamic changes in rat cortical vessels associated with electrical forepaw stimulation. Imaging of blood optical absorption by fPAM at multiple appropriately-selected and distinct wavelengths can be used to probe changes in total hemoglobin concentration (HbT, i.e., cere...

متن کامل

Calibration-free quantification of absolute oxygen saturation based on the dynamics of photoacoustic signals.

Photoacoustic tomography (PAT) is a hybrid imaging technique that has broad preclinical and clinical applications. Based on the photoacoustic effect, PAT directly measures specific optical absorption, which is the product of the tissue-intrinsic optical absorption coefficient and the local optical fluence. Therefore, quantitative PAT, such as absolute oxygen saturation (sO₂) quantification, req...

متن کامل

Imaging of an Inflammatory Injury in the Newborn Rat Brain with Photoacoustic Tomography

BACKGROUND The precise assessment of cerebral saturation changes during an inflammatory injury in the developing brain, such as seen in periventricular leukomalacia, is not well defined. This study investigated the impact of inflammation on locoregional cerebral oxygen saturation in a newborn rodent model using photoacoustic imaging. METHODS 1 mg/kg of lipopolysaccharide(LPS) diluted in salin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2010