A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers
نویسندگان
چکیده
Advances in the field of quantum sensing mean that magnetic field sensors, operating at room temperature, are now able to achieve sensitivity similar to that of cryogenically cooled devices (SQUIDs). This means that room temperature magnetoencephalography (MEG), with a greatly increased flexibility of sensor placement can now be considered. Further, these new sensors can be placed directly on the scalp surface giving, theoretically, a large increase in the magnitude of the measured signal. Here, we present recordings made using a single optically-pumped magnetometer (OPM) in combination with a 3D-printed head-cast designed to accurately locate and orient the sensor relative to brain anatomy. Since our OPM is configured as a magnetometer it is highly sensitive to environmental interference. However, we show that this problem can be ameliorated via the use of simultaneous reference sensor recordings. Using median nerve stimulation, we show that the OPM can detect both evoked (phase-locked) and induced (non-phase-locked oscillatory) changes when placed over sensory cortex, with signals ~4 times larger than equivalent SQUID measurements. Using source modelling, we show that our system allows localisation of the evoked response to somatosensory cortex. Further, source-space modelling shows that, with 13 sequential OPM measurements, source-space signal-to-noise ratio (SNR) is comparable to that from a 271-channel SQUID system. Our results highlight the opportunity presented by OPMs to generate uncooled, potentially low-cost, high SNR MEG systems.
منابع مشابه
Measurement of the Earth’s Magnetic Field Vector based on zero field finding algorithm using optically pumped magnetometers
Atomic magnetometers have found widespread applications in precise measurement of the Earth’s magnetic field due to their high sensitivity. In these measurements, various methods have been utilized to compensate the Earth’s magnetic field in an unshielded environment. In this paper, we have proposed a method based on finding the minimum resonance frequency (corresponding to minimum magnetic fie...
متن کاملOptically-Pumped Magnetometers for MEG
Optically-pumped magnetometers (OPMs) have seen rapid progress over the last decade in terms of performance and technology development. As highly sensitive room-temperature magnetometers they present several advantages over superconducting quantum interference device (SQUID) sensors, such as the possibility for conformal geometries and low-maintenance systems. We review the state of the art and...
متن کاملHigh Sample Rate Optically Pumped Helium Magnetometer
Optically pumped helium magnetometers are important instruments whichhave many applications in military, mass spectroscopy and space applications. In thispaper, the working principles of helium magnetometers have been explained. There isalso an introduction of a new method for finding the resonant frequency, which hasadvantages to the typical method such as more sample r...
متن کاملMagnetocardiography measurements with 4He vector optically pumped magnetometers at room temperature.
In this paper, we present a proof of concept study which demonstrates for the first time the possibility of recording magnetocardiography (MCG) signals with 4He vector optically pumped magnetometers (OPM) operated in a gradiometer mode. Resulting from a compromise between sensitivity, size and operability in a clinical environment, the developed magnetometers are based on the parametric resonan...
متن کاملFetal magnetocardiography measurements with an array of microfabricated optically pumped magnetometers.
Following the rapid progress in the development of optically pumped magnetometer (OPM) technology for the measurement of magnetic fields in the femtotesla range, a successful assembly of individual sensors into an array of nearly identical sensors is within reach. Here, 25 microfabricated OPMs with footprints of 1 cm(3) were assembled into a conformal array. The individual sensors were inserted...
متن کامل