Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures

نویسندگان

  • Julia Loesaus
  • Isabel Wobbe
  • Erik Stahlberg
  • Joerg Barkhausen
  • Jan Peter Goltz
چکیده

AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity. METHODS Retrospectively we identified 89 consecutive patients (41 female, mean age 49 ± 18 years) who had X-ray (CR) and computed tomography (CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex (PQC) was measured using lateral views (CR) and sagittal reconstructions (CT). Pearson's test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign (PQS) was defined as a PQC > 8.0 mm (female) or > 9.0 mm (male). Frykman classification was utilized to assess the severity of fractures. RESULTS Forty-four/89 patients (49%) had a distal radius fracture (Frykman I n = 3, II n = 0, III n = 10, IV n = 5, V n = 2, VI n = 2, VII n = 9, VIII n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views (CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions (CT), resulting in a significant correlation coefficient of 0.795. A positive PQS at CR was present in 21/44 patients (48%) with distal radius fracture and in 2/45 patients (4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures. CONCLUSION A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical study of the Pronator Quadratus muscle: anatomical features and feasibility of Pronator-Sparing Surgery

BACKGROUND No clinical data for the relationship of pronator quadratus (PQ) muscle to distal radius had been reported. The aim of this study was to investigate the anatomical features of the PQ muscle related to plate osteosynthesis for distal radius fractures in clinical cases. The feasibility of PQ muscle sparing surgery was investigated as well. METHODS Fifty two distal radius fractures (2...

متن کامل

Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review

To position the volar plate on the distal radius fracture site, the pronator quadratus muscle needs to be detached from its distal and radial side and lifted for optimal exposure to the fracture site. Although the conventional approach involves repair of the pronator quadratus, controversy surrounds the merits of this repair. The purpose of this study was to compare the functional outcomes of p...

متن کامل

Flexor Pollicis Longus Tendon Rupture After Volar Plating of a Distal Radius Fracture: Pronator Quadratus Plate Coverage May Not Adequately Protect Tendons

OBJECTIVE The senior author previously reported a case of rupture of the flexor policis longus tendon after volar plating of a distal radius fracture. We hypothesized that restoration of the pronator quadratus to its native position after plating might prevent this problem. METHODS The authors report a new case of irritation of the flexor policis longus 2.5 years after volar plating of a dist...

متن کامل

A coincidental anterior interosseous nerve palsy after volar plate fixation of a distal radius fracture diagnosed by 3D-CT.

A case presented dysfunctional flexion of the thumb and index fingers after volar plate fixation for of distal radius fractures was diagnosed anterior interosseous nerve palsy and confirmed by 3D-CT. 3D-CT was useful to confirm the continuities of tendons, which excluded the most common complication of tendon ruptures after volar plate fixation. Also, it was superior to needle electromyography ...

متن کامل

Examination of the Pronator Quadratus Muscle during Hardware Removal Procedures after Volar Plating for Distal Radius Fractures

BACKGROUND It is not clear whether the pronator quadratus (PQ) muscle actually heals and provides a meaningful pronation force after volar plating for distal radius fractures (DRFs). We aimed to determine whether the length of the PQ muscle, which is dissected and then repaired during volar plating for a DRF, affects the forearm rotation strength and clinical outcomes. METHODS We examined 41 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017