The endotracheal tube cuff-leak test as a predictor for postextubation stridor.

نویسندگان

  • Eric J Kriner
  • Shirin Shafazand
  • Gene L Colice
چکیده

BACKGROUND The endotracheal tube (ETT) cuff-leak test (CLT) has been proposed as a relatively simple, noninvasive method for detecting the presence of laryngeal edema prior to tracheal extubation. OBJECTIVE To determine the value of the CLT for predicting postextubation stridor (PES) among medical and surgical patients, and to assess the impact of certain variables on the incidence of PES. METHODS We conducted a prospective, observational study in the intensive care unit at Washington Hospital Center, a 907-bed acute care hospital in Washington DC, with patients who were intubated for > 24 h. As part of respiratory therapy quality assurance, patients intubated for > 24 h are evaluated daily for extubation readiness, and CLT is conducted prior to extubation. The CLT results and the postextubation outcomes were prospectively recorded for 6 months. RESULTS Of the 462 patients studied, 20 (4.3%) developed PES that required treatment; 7 of those 20 (1.5%) required reintubation. With patients who failed the CLT, defined by an absolute leak volume < or = 110 mL, the positive predictive value for PES was 0.12, the negative predictive value was 0.97, the sensitivity was 0.50, and the specificity was 0.84. Using different definitions for CLT failure did not improve the accuracy of CLT for predicting PES. Patients who had PES were more likely to be female (6.5% vs 2.4%, p = 0.04), to have a longer duration of translaryngeal intubation (6.5 + 4 d vs 4.5 + 4 d, p = 0.02), and to have a larger ratio of ETT size to laryngeal size (49.5 + 6% vs 45.5 + 6%, p = 0.01). CONCLUSIONS Failing the CLT was not an accurate predictor of PES and should not be used as an indication for either delaying extubation or initiating other specific therapy. Female patients, those whose ratio of ETT size to laryngeal diameter was > 45%, and patients intubated for > 6 d were more likely to develop PES.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Limited value of the cuff-leak test.

Stridor following tracheal extubation occurs in approximately 5% of all patients, and approximately 1% of all patients require reintubation for upper-airway obstruction.1 Patients at increased risk for stridor and upper-airway obstruction following extubation include female patients; children,2 particularly those with acute respiratory-tract infections (croup);3 patients who have incurred facia...

متن کامل

Laryngeal Ultrasonography Versus Cuff Leak Test in Predicting Postextubation Stridor

INTRODUCTION Although cuff leak test has been proposed as a simple method of predicting the occurrence of postextubation stridor, cut-off point of cuff-leak volume substantially differs between previous studies. In addition, laryngeal ultrasonography including measurement of air column width could predict postextubation stridor. The aim of the present study was to evaluate the value of laryngea...

متن کامل

The role of the cuff leak test in predicting the effects of corticosteroid treatment on postextubation stridor.

BACKGROUND There is not enough evidence to determine the most appropriate treatment of postextubation stridor. Although the cuff leak test is a simple method to predict postextubation stridor, little is known about its use in monitoring the effects of steroid treatment for this complication. The aim of this study was to evaluate the effect of steroids on postextubation stridor based on the clin...

متن کامل

Postextubation laryngeal edema and stridor resulting in respiratory failure in critically ill adult patients: updated review

Endotracheal intubation is frequently complicated by laryngeal edema, which may present as postextubation stridor or respiratory difficulty or both. Ultimately, postextubation laryngeal edema may result in respiratory failure with subsequent reintubation. Risk factors for postextubation laryngeal edema include female gender, large tube size, and prolonged intubation. Although patients at low ri...

متن کامل

The endotracheal tube air leak test does not predict extubation outcome in critically ill pediatric patients.

OBJECTIVE Endotracheal tube air leak pressures are used to predict postextubation upper airway compromise such as stridor, upper airway obstruction, or risk of reintubation. To determine whether the absence of an endotracheal tube air leak (air leak test >/=30 cm H2O) measured during the course of mechanical ventilation predicts extubation failure in infants and children. DESIGN Prospective, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 50 12  شماره 

صفحات  -

تاریخ انتشار 2005