Dose distribution verification for GZP6 sources: a comparison of Monte Carlo, radiochromic film, and GZP6 treatment planning system
نویسندگان
چکیده
www.onk.ns.ac.rs/Archive Vol 20, No. 1–2, July 2012 INTRODUCTION The GZP6 high dose rate (HDR) afterloading brachytherapy unit (Nuclear Power Institute of China) (1) has recently been introduced in the Iranian radiation oncology centers. The unit has six different cobalt-60 source braids being loaded in tandem and ovoid applicators. The sources are used in the treatment of cervix, vagina, rectum, esophagus, and a number of other cancers. The unit has a treatment planning system, which presents dose distributions for different insertions in terms of isodose curves (2). In dose delivery by brachytherapy systems, the delivered dose to the target volume and the dose received by the adjacent critical organs are calculated using dose distributions presented by treatment planning system (3). The treatment planning systems commonly calculate the dose distributions by assuming each source as a point source. The source capsule, inter-pellet attenuation, and scattering are not also incorporated in the algorithms used in the treatment planning system for dose calculations (4). Since the treatment planning systems use simplified algorithms in their dose calculations, verification of the dose distributions presented by the systems may be of clinical importance (5). Evaluation of the treatment planning systems in terms of their presented dose distribution can be a part of quality assurance in the clinical practice of brachytherapy (6). There are scarce studies conducted on GZP6 unit focusing on the calculation and measurement of task group number 43 (TG-43) (7) parameters for different sources of the GZP6 unit (8, 9). In our previous study, an evaluation verifying the dose distribution around the first source of GZP6 unit was performed (10). Naseri et al. have studied dose distribution around the source number one, two, and five of the unit but their study was for a vaginal applicator and was based on relative dose evaluations (2). To our knowledge there is no other study verifying dose distributions around source braids of this unit. In this study, the dose distributions presented by GZP6 treatment planning system for the source braids No. 2 and No. 5 were evaluated based on Monte Carlo simulations and inphantom radiochromic film measurements.
منابع مشابه
Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations
Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three 60Co sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a go...
متن کاملApplication of a color scanner for 60Co high dose rate brachytherapy dosimetry with EBT radiochromic film
UNLABELLED BACKGROUND.: The aim of this study is to evaluate the performance of a color scanner as a radiochromic film reader in two dimensional dosimetry around a high dose rate brachytherapy source. MATERIALS AND METHODS A Microtek ScanMaker 1000XL film scanner was utilized for the measurement of dose distribution around a high dose rate GZP6 (60)Co brachytherapy source with GafChromic® EBT...
متن کاملEvaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...
متن کاملDesign and Implementation of a Complementary Treatment Planning Software for the GZP6 HDR Brachytherapy System (GZP6 CTPS)
Introduction: Brachytherapy is one of the most common treatment modalities for gynecological cancer. The GZP6 brachytherapy system is one of the devices utilized in Iran. It has been considered particularly due to its low cost compared to other more complete and established systems. This system has some deficiencies including lack of a treatment planning software for non-predefined treatments, ...
متن کاملDosimetric characterizations of GZP6 60Co high dose rate brachytherapy sources: application of superimposition method
BACKGROUND Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. MATERIALS AND METHODS MCNP-4C and MCNPX Monte Carlo codes were utilized to calculate dose rate constant, two dimensional (2D) dose distribution...
متن کامل