. 2 Supplementum 3 2003 Body Composition Assessment with Segmental Multifrequency Bioimpedance Method

نویسندگان

  • Jukka A. Salmi
  • Harri Sievänen
  • Mikael Fogelholm
چکیده

Body composition assessment is an important factor in weight management, exercise science and clinical health care. Bioelectrical impedance analysis (BIA) is widely used method for estimating body composition. The purpose of this study was to evaluate segmental multi-frequency bioimpedance method (SMFBIA) in body composition assessment with underwater weighing (UWW) and whole body dual energy x-ray absorptiometry (DXA) in healthy obese middle-aged male subjects. The measurements were carried out at the UKK Institute for Health Promotion Research in Tampere, Finland according to standard procedures of BIA, UWW and DXA. Fifty-eight (n=58) male subjects, aged 36-53 years, body mass index (BMI) 24.9-40.7, were studied. Of them forty (n=40) underwent also DXA measurement. Fat mass (FM), fat-percentage (F%) and fat free mass (FFM) were the primary outcome variables. The mean whole body FM (+SD) from UWW was 31.5 kg (±7.3). By DXA it was 29.9 kg (±8.1) and by SMFBIA it was 25.5 kg (±7.6), respectively. The Pearson correlation coefficients (r) were 0.91 between UWW and SMFBIA, 0.94 between DXA and SMFBIA and 0.91 between UWW and DXA, respectively. The mean segmental FFM (+SD) from DXA was 7.7 kg (±1.0) for arms, 41.7 kg (±4.6) for trunk and 21.9 kg (±2.2) for legs. By SMFBIA, it was 8.5 kg (±0.9), 31.7 kg (±2.5) and 20.3 kg (±1.6), respectively. Pearson correlation coefficients were 0.75 for arms, 0.72 for legs and 0.77 for trunk. This study demonstrates that SMFBIA is usefull method to evaluate fat mass (FM), fat free mass (FFM) and fat percentage (F%) from whole body. Moreover, SMFBIA is suitable method for assessing segmental distribution of fat free mass (FFM) compared to whole body DXA. The results of this study indicate that the SMFBIA method may be particularly advantageous in large epidemiological studies as being a simple, rapid and inexpensive method for field use of whole body and segmental body composition assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Analysis of Multisine and Binary Excitation Signals for Human Body Analysis

Bioimpedance analysis (BIA) is a potential field and clinical method for evaluating fat percentage and body mass. Multi-frequency bioimpedance monitoring methodology used for the analysis purpose is a widely used method to estimate body composition. The multifrequency bioimpedance analysis using network analyzer is a relatively quick, simple and non-invasive technique to measure body compositio...

متن کامل

Intra-abdominal fat: Comparison of computed tomography fat segmentation and bioimpedance spectroscopy

BACKGROUND Intra-abdominal fat is an important factor in determining the metabolic syndrome/insulin resistance, and thus the risk of diabetes and ischaemic heart disease. Computed Tomography (CT) fat segmentation represents a defined method of quantifying intra-abdominal fat, with attendant radiation risks. Bioimpedance spectroscopy may offer a method of assessment without any risks to the pati...

متن کامل

Assessment of body cell mass at bedside in critically ill patients.

Critical illness affects body composition profoundly, especially body cell mass (BCM). BCM loss reflects lean tissue wasting and could be a nutritional marker in critically ill patients. However, BCM assessment with usual isotopic or tracer methods is impractical in intensive care units (ICUs). We aimed to modelize the BCM of critically ill patients using variables available at bedside. Fat-fre...

متن کامل

Evaluation of the predictive capacity of vertical segmental tetrapolar bioimpedance for excess weight detection in adolescents.

OBJECTIVE To analyze the predictive capacity of the vertical segmental tetrapolar bioimpedance apparatus in the detection of excess weight in adolescents, using tetrapolar bioelectrical impedance as a reference. METHODS This was a cross-sectional study conducted with 411 students aged between 10 and 14 years, of both genders, enrolled in public and private schools, selected by a simple and st...

متن کامل

Effect of diurnal variation on body composition under consideration of selected chronobiological marker systems

Diurnal variation in body composition in relation to chronobiological parameters was analyzed in 27 healthy students (22-29 years) four times over one day from 5:35 to 0:15 h. Body composition was determined by multifrequency bioimpedance analysis at fixed frequencies (1, 5, 50, 100 kHz). Resistance (R) and reactance (Xc) were measured. Total, extra and intracellular body water (TBW, ECW, ICW),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006