Endovascular treatment of experimental wide neck aneurysms: comparison of results using coils or cyanoacrylate with the assistance of an aneurysm neck bridge device.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Endovascular treatment of wide neck aneurysms often results in incomplete occlusion or aneurysm recurrence. The two goals of the present study were to compare results of coil embolization with or without the assistance of an aneurysm neck bridge device (ANBD) and to explore the use of this instrument to control cyanoacrylate embolization. METHODS Wide necked bifurcation aneurysms were constructed in 28 dogs. Coil embolization of the aneurysms was performed 2 to 4 weeks later, with (n = 11) or without (n = 10) ANBD assistance. In seven other animals, embolization was performed with cyanoacrylate, injected under the protection of ANBDs. Angiographic results were compared immediately after and at 3 and 12 weeks. Neointima formation at the neck was also compared between groups at 12 weeks. RESULTS Initial angiographic results and recurrences at 12 weeks were not significantly different in aneurysms coiled with or without ANBDs. Neointimal scores were also similar. The use of one ANBD at the neck was not sufficient to safely deliver cyanoacrylate into aneurysms. Cyanoacrylate embolization led to improved angiographic results (P =.05) and to better neointimal sealing of the neck of the aneurysms at 12 weeks (P =.004). CONCLUSION ANBDs did not prevent recanalization and recurrences after coil embolization of wide neck aneurysms in this animal study. ANBD-assisted cyanoacrylate embolization was unsafe but could decrease recurrences at 12 weeks.
منابع مشابه
Cyanoacrylate embolization of experimental aneurysms.
BACKGROUND AND PURPOSE Cyanoacrylates are effective occlusive agents in neurovascular interventions. To study their potential to improve long-term results of endovascular treatment of aneurysms, we conducted experimental studies in canine aneurysm models. METHODS Venous pouch carotid aneurysms were constructed in dogs. Results of coil embolization of lateral wall and bifurcation aneurysms wer...
متن کاملEndovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results.
PURPOSE To devise a method to measure aneurysm neck size on angiographic films, and to correlate the sizes obtained with the extent of endovascular aneurysm occlusion, performed with electrically detachable coils. METHODS The angiograms of 79 intracranial aneurysms treated by endovascular occlusion using electrically detachable coils were retrospectively analyzed. A method using the average r...
متن کاملEndovascular Management of the Wide-neck Aneurysms: the Applications of the Coils and Catheter
aneurysms has become an accepted treatment option worldwide (1). However, principal disadvantage of embolization of aneurysms with detachable coils is that embolization could be limited by unfavorable shape of the aneurysms (2-5). Coils packed into the lumen of the wide-neck aneurysms have the inherent difficulty that coils can herniate into the parent vessels. The wide-neck of aneurysms also u...
متن کاملNovel aneurysm neck reconstruction device: initial experience in an experimental preclinical bifurcation aneurysm model
INTRODUCTION Treatment of wide-necked bifurcation aneurysms often poses procedural and long-term outcome challenges. The initial preclinical experience with the Pulsar Vascular Aneurysm Neck Reconstruction Device (PVANRD) in a canine bifurcation model is described. METHODS Experimental bifurcation vein pouch aneurysms were surgically created in the carotid arteries of eight dogs. Endovascular...
متن کاملUse of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms.
A three-dimensional Guglielmi detachable coil (3D-GDC) has been developed that is designed specifically to bridge the neck of an aneurysm with coil loops, thereby facilitating retention of additional coils placed within the aneurysm. Nine wide-necked cerebral aneurysms were successfully embolized using the 3D-GDC, provided that the dome-to-neck ratio was 1.5 or greater.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 23 10 شماره
صفحات -
تاریخ انتشار 2002