Deformation of nickel-titanium closed coil springs: an in vitro study

نویسندگان

  • Camilla Ivini Viana Vieira
  • José Maurício dos Santos Nunes Reis
  • Luiz Geraldo Vaz
  • Lídia Parsekian Martins
  • Renato Parsekian Martins
چکیده

OBJECTIVE The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. METHODS A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and activated from 100% to 1000% of the effective length of the nickel-titanium portion present at the spring, at 37 °C. Deactivation data were plotted and deformation was found graphically. The values were compared by analysis of variance and Tukey's post-hoc test. RESULTS Springs manufactured by Morelli had the same amount of deformation when they were activated up to 700% of Y activation; springs by Orthometric had the same amount of deformation up to 600-700% of Y; springs by Ormco had the same amount of deformation up to 700-800% of Y; and finally, the majority of springs by GAC had similar deformation up to 800%-1000% of activation. All springs tested could be activated up to 700% without rupture. CONCLUSIONS Most subgroups were similarly deformed up to 700% of activation, without rupture of springs. Subgroups 4B, 4C, 4D and 4E showed the same amount of deformation up to 1000% of activation without any rupture at all.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of aging process and preactivation on mechanical properties of nickel-titanium closed coil springs

BACKGROUND The most favorable feature of nickel-titanium (Ni-Ti) alloys in orthodontics is producing constant forces in a wide deformation range. Ni-Ti closed coils produce compressive strength and can be used for several purposes such as space closure. The aim of this study was to evaluate the effects of the aging process (temperature changes and prolonged strain) on Ni-Ti closed coils and to ...

متن کامل

Effects of Topical Fluoride Prophylactic Agents on the Mechanical Properties of Orthodontic Nickel-titanium Closed Coil Springs and Stainless Steel Closed Coil Springs

The purpose of this study was to investigate the effects of topical fluoride prophylactic agents on the mechanical unloading properties of nickel-titanium (NiTi) and stainless steel (SS) closed coil springs. Spring were stored at 37 ̊C under static load in phosphate buffered saline (PBS) and treated with either neutral sodium fluoride (NaF) or acidulated phosphate fluoride (APF) five days per we...

متن کامل

Superelasticity and force plateau of nickel-titanium springs: an in vitro study

OBJECTIVE This paper analyzed whether nickel-titanium closed coil springs (NTCCS) have a different superelastic (SE) behavior according to activation and whether their force plateau corresponds to that informed by the manufacturer. METHODS A total of 160 springs were divided into 16 subgroups according to their features and activated proportionally to the length of the extensible part (NiTi) ...

متن کامل

Mechanical behavior and clinical application of nickel-titanium closed-coil springs under different stress levels and mechanical loading cycles.

INTRODUCTION The main advantage of superelastic nickel-titanium (NiTi) products is their unique characteristic of force plateaus, which allow for clinically precise control of the force. The aims of this study were to define the mechanical characteristics of several currently available closed-coil retraction springs and to compare these products. METHODS A universal test frame was used to acq...

متن کامل

Intrusion of palatally displaced maxillary lateral incisors using nickel titanium closed-coil springs.

eral incisors. EW springs were then bonded to anchor-wire segments as described above (Fig. 3). Three months later, the upper lateral incisors had been significantly intruded (Fig. 4). After the intrusion auxiliaries were removed, a bracket was bonded to the left lateral incisor for incorporation into the main archwire; an .008" ligature wire was bonded to the surface of the right lateral incis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2017