Application of large-area avalanche photodiodes to X-ray spectrometry of muonic atoms

نویسنده

  • F. Kottmann
چکیده

Large-area avalanche photodiodes have been investigated as 1.9-keV X-ray detectors for the muonic hydrogen Lamb-shift experiment. We report experimental tests carried out for evaluation of the avalanche photodiode capabilities for X-ray detection in the intense radiation and low counting rate environment of experiments with muonic atoms. Several muonic atoms were used and it was shown that the electronic background of muonic atom X-ray spectra can be reduced simply by timing the X-ray signal against the gate signal produced by the muon entrance. Furthermore, the background can be eliminated using coincidences between the X-ray signal and the signal resulting from the electron due to the muon decay. This coincidence discrimination results, however, in a reduction of the X-ray detection efficiency. 2003 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of large-area avalanche photodiodes to energy-dispersive x-ray fluorescence analysis

The performance of several large-area avalanche photodiodes (LAAPDs) for application to x-ray spectrometry at room temperature was investigated. Optimum detector performance was obtained for gains of about 50–70. Good energy linearity of the LAAPDs’ response to x-rays was observed up to energies of about 25 keV. For this energy range the space charge effects are negligible for gains below 100–1...

متن کامل

X-ray spectrometry with Peltier-cooled large area avalanche photodiodes

Performance characteristics of the response of a Peltier-cooled large-area avalanche photodiode are investigated. Detector gain, energy linearity, energy resolution and minimum detectable energy are studied at different operation temperatures. Detector energy resolution and lowest detectable X-ray energy present a strong improvement as the operation temperature is reduced from 25 to 15 C and sl...

متن کامل

Large area APDs for low energy X-ray detection in intense magnetic fields

An experiment to measure the energy difference between the 2S–2P atomic levels (Lamb shift) in muonic hydrogen is being prepared at PSI. Since the energy levels of muonic hydrogen are a factor of 186 more energetic than those of hydrogen, according to the ratio of reduced masses, the transitions lie in the soft X-ray region. The experiment needs long-lived muonic hydrogen in the 2S state. This ...

متن کامل

Response of large area avalanche photodiodes to low energy x rays.

For an experiment to study neutron radiative beta-decay, we operated large area avalanche photodiodes (APDs) near liquid nitrogen temperature to detect x rays with energies between 0.2 keV and 20 keV. Whereas there are numerous reports of x ray spectrometry using APDs at energies above 1 keV, operation near liquid nitrogen temperature allowed us to reach a nominal threshold of 0.1 keV. However,...

متن کامل

Non-linear behaviour of large-area avalanche photodiodes

The characterisation of photodiodes used as photosensors requires a determination of the number of electron–hole pairs produced by scintillation light. One method involves comparing signals produced by X-ray absorptions occurring directly in the avalanche photodiode with the light signals. When the light is derived from light-emitting diodes in the 400–600 nm range, significant non-linear behav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003