A Raster Scanning Reflectance Imager for Non-Model Based Quantification of Tissue Scatter

نویسندگان

  • Venkataramanan Krishnaswamy
  • P. Jack Hoopes
  • Kimberley S. Samkoe
  • Brian W. Pogue
چکیده

It has been shown that locally resolved reflectance measurements can directly quantify scatter changes in tissues without the need for computationally expensive model-based reconstruction schemes. Imaging systems exploiting non-model based reconstruction schemes are faster compared to the conventional model based schemes and thus have the potential for imaging tissue pathologies in real-time. In this report, the scanning system is described in terms of the design, construction and testing for multi-wavelength reflectance imaging capable of measuring scatter changes with 100 micron resolution of tissue. Imaging fields of up to 256 by 256 pixels were used in this current system, with a design for a 100 micron spot to allow sampling of the local scatter values in this size of region. Tissue phantoms with varying scattering and absorption profiles within the region of interest were used to test the performance of this system. The results demonstrate the ability of the instrument to measure scatter changes independent of local absorber concentration. This new scanning system should allow visualization of tumor-associated scatter changes in situ, with full spectral resolution across the visible range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

A new approach to scatter correction in SPECT images based on Klein_Nishina equation

Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...

متن کامل

Camera based EPID dosimetric verification of radiation treatments

Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context.   Materials and Methods: In this study, ...

متن کامل

A CMOS active pixel sensor system for laboratory- based x-ray diffraction studies of biological tissue.

X-ray diffraction studies give material-specific information about biological tissue. Ideally, a large area, low noise, wide dynamic range digital x-ray detector is required for laboratory-based x-ray diffraction studies. The goal of this work is to introduce a novel imaging technology, the CMOS active pixel sensor (APS) that has the potential to fulfil all these requirements, and demonstrate i...

متن کامل

Adjustment of Sentinel-2 Multi-Spectral Instrument (MSI) Red-Edge Band Reflectance to Nadir BRDF Adjusted Reflectance (NBAR) and Quantification of Red-Edge Band BRDF Effects

Optical wavelength satellite data have directional reflectance effects over non-Lambertian surfaces, described by the bidirectional reflectance distribution function (BRDF). The Sentinel-2 multi-spectral instrument (MSI) acquires data over a 20.6◦ field of view that have been shown to have non-negligible BRDF effects in the visible, near-infrared, and short wave infrared bands. MSI red-edge BRD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008