Evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides

نویسندگان

  • Sylwia Studzińska
  • Bogusław Buszewski
چکیده

Ultra high-performance [corrected] liquid chromatography has been used for the separation and analysis of unmodified and modified antisense oligonucleotides. For this reason, we tested various columns of low particle sizes in our analysis of unmodified and phosphorothioate oligonucleotides. The influence of both the type and concentration of ion-pair reagent on the retention of the studied biomolecules was tested. The developed methods were used for separation of unmodified oligonucleotides and to determine antisense oligonucleotides in human serum samples. The results proved that octadecyl and phenyl columns are the most selective in the resolution of oligonucleotides which differ in the position of single nucleotides in the sequence. The phenyl column was selected and applied for the analysis of phosphorothioate oligonucleotides in serum samples. The calibration plots showed good linearity within the test concentration ranges. The intra-day CV of the calibration curve slopes was in the range of 1.6 to 4.2 %. The limits of detection (LODs) were in the range of 0.11-0.16 μg mL(-1), while the limit of quantification (LOQ) values were between 0.35 and 0.51 μg mL(-1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum to: Evaluation of ultra high performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides

The publisher regrets that the following correction was not implemented in the final proof of this contribution. It should read throughout the entire article " ultra high performance liquid chromatography ". Our sincere apologies to the authors.

متن کامل

Restoration of correct splicing in IVSI-110 mutation of β-globin gene with antisense oligonucleotides: implications and applications in functional assay development

Objective(s): The use of antisense oligonucleotides (AOs) to restore normal splicing by blocking the recognition of aberrant splice sites by the spliceosome represents an innovative means of potentially controlling certain inherited disorders affected by aberrant splicing. Selection of the appropriate target site is essential in the success of an AO therapy. In this study, in search for a splic...

متن کامل

High performance liquid chromatographic analysis of reduction products of a thiolated DNA for immobilization on gold nanoparticles

DNA-based nano-biosensors are emerging scope in the field of biosensors. Many synthetic single stranded functional DNAs have been applied for development of such sensors, recently. Immobilization of DNA oligonucleotides on the surface of gold nanoparticles is a key step in the development of most colorimetric nano-biosensors. The bound DNA is usually thiolated and forms Au-S covalent bond to th...

متن کامل

Fabrication of a Voltammetric Biosensor in Combination with Enzyme-linked Immunosorbent Assay to Detect Aflatoxin M1 in Milks

Background and Objectives: Aflatoxin M1 is one the most important mycotoxin contaminants of milks. Various methods have been described to detect aflatoxins in milks, including chromatography, enzyme-linked immunosorbent assay and colorimetry. Regarding high sensitivity of electrochemical sensor based methods, the aim of the present study was to fabricate an accurate sensitive voltametric biosen...

متن کامل

Rapid high performance liquid chromatography method development with high prediction accuracy, using 5cm long narrow bore columns packed with sub-2microm particles and Design Space computer modeling.

Many different strategies of reversed phase high performance liquid chromatographic (RP-HPLC) method development are used today. This paper describes a strategy for the systematic development of ultrahigh-pressure liquid chromatographic (UHPLC or UPLC) methods using 5cmx2.1mm columns packed with sub-2microm particles and computer simulation (DryLab((R)) package). Data for the accuracy of comput...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 406  شماره 

صفحات  -

تاریخ انتشار 2014