Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography.
نویسندگان
چکیده
A double-beam polarization-sensitive system based on optical coherence tomography was built to measure the Mueller matrix of scattering biological tissue with high spatial resolution. The Jones matrix of a sample can be determined with a single scan and subsequently converted into an equivalent nondepolarizing Mueller matrix. As a result, the system can be used to measure the Mueller matrix of an unstable sample, such as soft tissue. The polarization parameters of a porcine tendon, including magnitude and orientation of birefringence and diattenuation, were extracted by decomposition of the measured Mueller matrix.
منابع مشابه
Depth-resolved two-dimensional stokes vectors of backscattered light and mueller matrices of biological tissue measured with optical coherence tomography.
Mueller matrices provide a complete characterization of the optical polarization properties of biological tissue. A polarization-sensitive optical coherence tomography (OCT) system was built and used to investigate the optical polarization properties of biological tissues and other turbid media. The apparent degree of polarization (DOP) of the backscattered light was measured with both liquid a...
متن کاملTime-domain Polarization-sensitive Optical Coherence Tomography in Soft Biological Tissue
Time-Domain Polarization-Sensitive Optical Coherence Tomography in Soft Biological Tissue. (August 2008) Milos Todorovic, B.S., University of Belgrade; M.S., Texas A&M University Co-Chairs of Advisory Committee, Dr. Lihong V. Wang Dr. Gerard L. Cote A new, high-speed, fiber-based Mueller-matrix optical coherence tomography system with continuous source-polarization modulation is presented. For ...
متن کاملJones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography.
Two-dimensional depth-resolved Jones-matrix images of scattering biological tissues were measured with novel double-source double-detector polarization-sensitive optical coherence tomography (OCT). The Jones matrix can be determined in a single scan with this OCT system. The experimental results show that this system can be effectively applied to the measurement of soft tissues, which are less ...
متن کاملContrast mechanisms in polarization-sensitive Mueller-matrix optical coherence tomography and application in burn imaging.
We investigate the various contrast mechanisms provided by polarization-sensitive (PS) Mueller-matrix optical coherence tomography (OCT). Our PS multichannel Mueller-matrix OCT is the first, to our knowledge, to offer simultaneously comprehensive polarization-contrast mechanisms, including the amplitude of birefringence, the orientation of birefringence, and the diattenuation in addition to the...
متن کاملFiber-based polarization-sensitive Mueller matrix optical coherence tomography with continuous source polarization modulation.
We report on a new configuration of fiber-based polarization-sensitive Mueller matrix optical coherence tomography that permits the acquisition of the round-trip Jones matrix of a biological sample using only one light source and a single depth scan. In this new configuration, a polarization modulator is used in the source arm to continuously modulate the incident polarization state for both th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics letters
دوره 27 2 شماره
صفحات -
تاریخ انتشار 2002