Experimental Performance of Window Air Conditioner Using Alternative Refrigerants with Different Configurations of Capillary Tube A Review
نویسنده
چکیده
This review paper presents the work of various researches on the performance of capillary tube ,used in air conditioners with various refrigerants. Research carried out by different authors uses different type of capillary tubes (straight, twisted, coiled) in different length and diameter. they determined various parameters like coefficient of performance (COP),cooling capacity, energy efficiency ratio (EER) of the system. Various approaches have been used by different authors to predict the performance of capillary in window air conditioner using alternative refrigerant as capillary expansion device.
منابع مشابه
Window Air Conditioner with Orthodox Refrigerants
The system design of window air conditioner does not evolve in one day. Due to the continous efforts are taken by the refrigeration and air conditionging professionals, successful and economic models of window air conditioners are currently used. This paper states about the development of window air conditioner with phase change material and water as refrigerants. Developed air conditioner was ...
متن کاملA Performance of a Window Air Conditioner Using Alternative Refrigerants R22 AND R410A
This paper presents the experimental performance analysis of a window air conditioner using two refrigerants R22 and R410A.The effect of the different parameters of performance analysis (refrigeration capacity, COP, compressor power ,pressure ratio ) were investigated for various evaporating temperature and ambient temperature. .The result shows that refrigerant R22 is better than R410A in case...
متن کاملExperimental Study on the Performance of Twisted Capillary Tube
A novel capillary tube has been tested and evaluated experimentally in the refrigeration cycle of window type air conditioner. Three twisted capillary tubes have been demonstrated and evaluated to show the performance of these tubes and its ability in the depressurization process seeking for short capillary tube. The effect of twist angle and the number of twisted points on the refrigeration cy...
متن کاملRating Charts of R-22 Alternatives Flow through Adiabatic Capillary Tubes
Drop-in of R-22 alternatives in refrigeration and air conditioning systems requires a redesign of system components to improve system performance and reliability with the alternative refrigerants. The present paper aims at design adiabatic capillary tubes for R-22 alternatives such as R-417A, R-422D and R-438A. A theoretical model has been developed and validated with the available experimental...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013