Measurement of urinary constituents with the Astra-8 Multichannel Analyzer.
نویسندگان
چکیده
The Beckman Astra-8 is a computerized, discrete-microsample, multiple-test clinical chemistry analyzer. We have examined its capability to measure urine Na+, K+, Cl-, urea nitrogen, glucose, and creatinine and found that (a) the Astra measurements are linear, accurate, and precise in concentration ranges of urine analytes; (b) urine analyte concentrations measured with the Astra correlate well with those by comparison micromethods (p < 0.001); and (c) the Astra has no significant carryover from adjacent urine samples or from adjacent urine and serum samples.
منابع مشابه
Evaluation of a new multichannel analyzer, "Astra-8".
We evaluated a new multiple-channel chemistry analyzer, the Beckman "Astra-8," which is controlled by a microprocessor with 52K bytes of memory. The instrument we tested performed the following tests: Na, K, CO2, chloride, urea nitrogen, glucose, and creatinine. We compared the Astra-8 to a continuous-flow (SMA 6/60) and a discrete (Du Pont aca, urea nitrogen only) analyzer. The Astra-8 demonst...
متن کاملFactitiously high sodium activities on the Ektachem 400 owing to interferences by high gamma-globulin concentrations.
Sera from patients with above-normal gamma-globulin concentrations give sodium values as much as 10% higher when measured in the Kodak Ektachem 400 analyzer than results obtained with the Beckman Astra-8 analyzer. Results obtained with the Astra were in agreement with flame photometry. A similar relative bias was observed for potassium measurement in the Ektachem. This discrepancy was corrected...
متن کاملMeasurement of urinary chloride with the Kodak Ektachem 400.
Urinary chloride can be measured simply, precisely, and accurately with the Ektachem 400 clinical chemistry analyzer. Because the coated film technique used in this instrument requires the presence of a protein matrix, we added a protein-based calibrator to the urine samples to overcome the low protein concentration in these specimens. Its advantages over a coulometric titration method (Astra a...
متن کاملIndustrial SO2 emission monitoring through a portable multichannel gas analyzer with an optimized retrieval algorithm
SO2 variability over a large concentration range and interferences from other gases have been major limitations in industrial SO2 emission monitoring. This study demonstrates accurate industrial SO2 emission monitoring through a portable multichannel gas analyzer with an optimized retrieval algorithm. The proposed analyzer features a large dynamic measurement range and correction of interferenc...
متن کاملFactors influencing normal reference intervals for creatinine, urea, and electrolytes in plasma, as measured with a Beckman Astra 8 Analyzer.
In a study of 514 healthy adults, we used a Beckman Astra 8 Analyzer to establish normal reference intervals for plasma creatinine, urea, and electrolytes. For potassium and chloride these were considerably lower and higher, respectively, than previously reported ranges. All of these analytes showed significant sex-related differences; all except chloride showed age-related changes. The relatio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 26 13 شماره
صفحات -
تاریخ انتشار 1980