Comparison of the clinical effectiveness between the streamlined liner of pharyngeal airway (SLIPA) and the laryngeal mask airway by novice personnel
نویسندگان
چکیده
BACKGROUND The aim of this study was to compare the streamlined liner of the pharynx airway (SLIPA) with the classic laryngeal mask airway when used by novice personnel. METHODS There were 114 patients enrolled into this study who underwent general anesthesia were randomly allocated into one of 2 groups; LMA group (n = 57) or SLIPA group (n = 57). After insertion, insertion success rate, insertion time, and hemodynamic responses to insertion were accessed. After surgery, postoperative airway morbidity (sore throat, dysphonia, dysphagia) were evaluated. RESULTS The SLIPA was successfully inserted in 96% of patients (55/57) and the LMA in 93% (53/57) (P = 0.408). First attempt success rates were 88% (44/57) and 77% (50/57) in the SLIPA and the LMA (P = 0.142). The successful insertion time in SLIPA group (33.4 ± 11.0 sec) was significantly shorter than that of LMA group (38.8 ± 16.6 sec) (P = 0.048) and the insertion time at the first attempt was also shorter in SLIPA group (31.0 ± 6.3 sec) than LMA group (34.7 ± 8.6 sec) (P = 0.013). There was no statistically significant difference between the two groups in hemodynamic responses and postoperative airway morbidity. CONCLUSIONS The SLIPA was similar to the LMA in insertion success rate, hemodynamic response, and postoperative airway morbidity by novice personnel. The insertion time at the first attempt and successful insertion time of the SLIPA were significantly shorter than those of the LMA. Therefore, the SLIPA could be a useful alternative to the LMA as primary SGA for novice personnel.
منابع مشابه
Brief review: the Cobra Perilaryngeal Airway (CobraPLA and the Streamlined Liner of Pharyngeal Airway (SLIPA) supraglottic airways.
PURPOSE To summarize the published literature related to two, new supraglottic airways (SGAs): the Cobra Perilaryngeal Airway (CobraPLA) and the Streamlined Liner of Pharyngeal Airway (SLIPA). SOURCE We identified original articles, through searches on Medline and PubMed, using the keywords 'Cobra', 'CobraPLA', 'Cobra-PLA', 'PLA', and 'SLIPA'. PRINCIPAL FINDINGS Searches identified 28 publi...
متن کاملمقایسه اثر بخشی ماسک حنجره ای کلاسیک (LMA ) با streamlined liner pharyngeal airway (SLIPA ) در بیهوشی عمومی
متن کامل
The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA™) compared with the laryngeal mask airway ProSeal™ during general anesthesia
BACKGROUND The aim of this study was to compare the streamlined liner of the pharynx airway (SLIPA), a new supraglottic airway device (SGA), with the laryngeal mask airway ProSeal (PLMA) during general anesthesia. METHODS Sixty patients were randomly allocated to two groups; a PLMA group (n = 30) or a SLIPA group (n = 30). Ease of use, first insertion success rate, hemodynamic responses to in...
متن کاملCase Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملComparing the efficacy and safety of laryngeal mask airway, streamlined liner of the pharyngeal airway and I-gel following tracheal extubation
Adverse events following surgical operations are common complications due to removal of tracheal tube in contrast to the tracheal intubation. Awareness about the new methods and strategies for tracheal tube extubation is necessary for a safe and successful extubation. Therefore, we aimed to assess the safety and efficacy of laryngeal mask airway (LMA), streamlined liner of the pharyngeal airway...
متن کامل