Cloud Point Extraction of Trace Amounts of Copper and Its Determination by Flow Injection Flame Atomic Absorption Spectrometry

نویسندگان

  • Neda Baghban
  • Ali Mohammad Haji Shabani
  • Abbas Ali Jafari
چکیده

A simple and convenient method based on cloud point extraction was proposed for the determination of copper. The extraction was carried out in the presence of 2-[(2-mercaptophenylimino)methyl]phenol (MPMP) as the chelating ligand and octylphenoxypolyethoxyethanol (Triton X-114) as the non-ionic surfactant. After phase separation, the surfactant rich phase containing the complex was diluted with 1.0 mol L solution of HNO3 in methanol and the analyte concentration was determined by flow injection flame atomic absorption spectrometry. Under the optimum conditions, an enhancement factor of 81 was obtained for the preconcentration of copper with 25 mL sample solution. The calibration graph was linear in the range of 1–150 μg L, the relative standard deviation (RSD) for ten replicate determinations at 80 μg L Cu level was 1.8 %, and the limit of detection (3 s) and quantification (10 s) were 0.15 and 0.50 μg L respectively. The accuracy of method was confirmed by analysis of certified reference materials and recovery experiments. The proposed method was successfully applied to the determination of copper in rice flour and water samples. (doi: 10.5562/cca1803)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction

A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-r...

متن کامل

Sepration and determination trace amount of cadmium ions in real and water samples by cloud point extraction - flame atomic absorption spectrophotometry after preconcentration with non-ionic surfactant Triton-X114

2-(3- indolyl) – 4,5 di phynyl imidazole.(IDPI) was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of cadmium. The method is based on the extraction of cadmium at pH= 7.0 by using non-ionic surfactant Triton-X114 and 2-(3- indolyl) – 4,5 di phynyl imidazole. (IDPI) as a chelating agent. The adopted concentrati...

متن کامل

Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry

Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...

متن کامل

Determination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination

Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...

متن کامل

Determination of Trace Amount of Zn2+ Ion in soil, blood and vegetable and water samples by Flame Atomic Absorption Spectrometry After Cloud Point Extraction Using Selective Synthesis Ligand2-(3- indolyl) – 4,5 di phynyl imidazole.

  Abstract A simple, sensitive and feasible cloud-point extraction (CPE) methodology has been developed for the separation and preconcentration of cadmium and lead ions in real samples. The metals in the aqueous solution were complexes with 2-(3- indolyl) - 4,5 di phynyl imidazole.(IDPI), at pH = 7.0 and Triton X-114 was added as surfactant. The variables effecting like concentration of Triton ...

متن کامل

Solid-phase Extraction Using Modified Carbon Nanotube and Cupferron Ligand for Preconcentration and Determination of Trace Amounts of Copper in Real Samples

A solid phase extraction procedure for simultaneous separation and preconcentration of traceamounts of Cu+2 ion from various real samples prior to its determination by flame atomicabsorption spectrometry has been developed. The proposed method is based on the utilization ofmultiwalled carbon nanotube in combination with Cupferron ligand as a solid phaseextractant. The influences of the analytic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012