Determination of anions using monolithic capillary column ion chromatography with end-to-end differential contactless conductometric detectors under resonance approach.

نویسندگان

  • Zhenli Zhang
  • Dongdong Li
  • Xueyong Liu
  • Qamar Subhani
  • Yan Zhu
  • Qi Kang
  • Dazhong Shen
چکیده

An end-to-end differential measurement approach with capacitively coupled contactless conductivity detection (C(4)D) was applied to anion-exchange monolithic capillary column ion chromatography. The column was prepared by thermally initiated radical polymerization of poly(glycidyl methacrylate) in a fused-silica capillary of 320 μm i.d. and modified by quaternary ammonium latex surface coating. Two C(4)Ds were placed near both ends of the capillary column and the output difference between them was measured. With 15 mM potassium hydrogen phthalate used as the eluent, good separation of a mixture of inorganic anions (F(-), Cl(-), NO(2)(-), NO(3)(-)) was achieved. The detection limits of conventional C(4)D are 1.6, 0.28, 0.53, and 0.47 mg L(-1) for F(-), Cl(-), NO(2)(-), and NO(3)(-), respectively. To further enhance the sensitivity, the capacitive impedance from C(4)D was neutralized by an inductive impedance from a piezoelectric resonator. An increase in sensitivity by a factor of 7-8 was achieved in the resonating C(4)D in comparison with the conventional C(4)D. The detection limits of the resonating C(4)D are 0.23, 0.041, 0.065, and 0.059 mg L(-1) for F(-), Cl(-), NO(2)(-), and NO(3)(-), respectively. The response of the resonating C(4)D was analyzed based on an equivalent circuit model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of a low impedance contactless conductometric detector for the determination of inorganic cations in capillary monolithic column chromatography.

Poly(glycidyl methacrylate) cation exchange monolithic column was prepared in fused-silica capillaries of 320 μm i.d. by thermally initiated radical polymerization and utilized in capillary ion chromatography. With 15 mM methanesulfonic acid as the mobile phase, the separations of a mixture of inorganic cations (Li(+), Na(+), NH(4)(+), K(+)) was tested by using a capacitively coupled contactles...

متن کامل

Use of contactless conductivity detection for non-invasive characterisation of monolithic stationary-phase coatings for application in capillary ion chromatography.

A capacitively-coupled contactless conductivity detector (C4D) has been utilised as an on-capillary detector within a capillary ion chromatograph, incorporating a reversed-phase monolithic silica capillary column semi-permanently modified with a suitable ionic surfactant. The monolithic capillary column (150 x 0.1 mm i.d.) was modified using sodium dioctyl sulfosuccinate (DOSS), an anionic surf...

متن کامل

Accurate non-invasive determination of pKa of surface functionalised ion exchange monoliths using capacitively coupled contactless conductivity detection.

The use of on-column capacitively coupled contactless conductivity detection for the accurate non-invasive visualisation of the pH dependence of covalently bound boronic acid groups within a monolithic polymeric capillary column is demonstrated.

متن کامل

Determination of amino acids by capillary electrophoresis with differential resonant contactless conductivity detector.

The impedance of a capacitively coupled contactless conductivity detector (C(4)D) in capillary electrophoresis (CE) was measured by an impedance analysis method. The influence of solution conductivity and capillary dimension on impedance parameters was investigated. Under the experimental conditions used, 86-99.9% of the total impedance of a C(4)D is composed by its imaginary part from the capi...

متن کامل

Rapid and simultaneous determination of tetrafluoroborate, thiocyanate and hexafluorophosphate by high-performance liquid chromatography using a monolithic column and direct conductivity detection.

A method was developed for fast and simultaneous determination of tetrafluoroborate (BF(4)(-)), thiocyanate (SCN(-)) and hexafluorophosphate (PF(6)(-)) by high-performance liquid chromatography using a silica-based monolithic column and direct (non-suppressed) conductivity detection. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e column with tetrabutylammonium hydroxi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 137 12  شماره 

صفحات  -

تاریخ انتشار 2012