Efficacy of intrathecal morphine for analgesia following elective cesarean section: comparison with previous delivery.
نویسندگان
چکیده
PURPOSE To determine the effect of intrathecal injection of morphine 0.2 mg on postoperative analgesia, activity and satisfaction after elective cesarean section. METHOD Forty-five parturients who had previously undergone cesarean section with spinal anesthesia without intrathecal morphine were enrolled in this randomized, double-blinded study. Group 1 received hyperbaric bupivacaine 10 mg intrathecally (IT) and group 2 received morphine 0.2 mg IT in addition to hyperbaric bupivacaine 10 mg IT. All subjects received 20 mg piroxicam rectally at the end of surgery and 18 hours after surgery. Side effects in the first 24 hours after delivery were recorded by a trained nurse. Pain, nausea, pruritus, and satisfaction during the first 24 hours were self-rated using a visual analog scale. Subjects also recorded their memories of these symptoms after their previous cesarean sections. The time to first request for additional analgesics (30 mg pentazocine intramuscularly), total dose of pentazocine within 24 hours postoperatively and nurse observations of walking status within 24 hours postoperatively were also recorded. RESULTS In the present cesarean sections, the duration of complete analgesia and the time to first request for additional analgesics were longer in group 2 than in group 1. Group 2 had higher satisfaction scores than group 1 in spite of their more severe pruritus and nausea during the first 24 hours after surgery. The percentage of patients who could not walk during the first 24 hours after cesarean section was higher in group 1 than in group 2. CONCLUSION The addition of morphine 0.2 mg to hyperbaric bupivacaine 0.5% by intrathecal injection reduced postoperative pain and analgesic use, and increased patient satisfaction following cesarean section. The combination of intrathecal injection of morphine and preventive NSAIDs can be easily administered in most hospitals, and is substantially less expensive than the new pain management technologies currently in use.
منابع مشابه
Determination of an effective dose of intrathecal morphine for pain relief after cesarean delivery.
UNLABELLED Very small doses of intrathecal (i.t.) morphine (25-200 microg) have been used in an effort to provide effective postoperative pain relief while minimizing side effects after cesarean delivery. We performed a double-blinded study in 40 patients presenting for elective cesarean delivery in which i.t. morphine was administered along with oral hydrocodone/acetaminophen and other medicat...
متن کاملObstetric Anesthesia Section Editor
Very small doses of intrathecal (IT) morphine (25– 200 mg) have been used in an effort to provide effective postoperative pain relief while minimizing side effects after cesarean delivery. We performed a doubleblinded study in 40 patients presenting for elective cesarean delivery in which IT morphine was administered along with oral hydrocodone/acetaminophen and other medications commonly admin...
متن کاملIntrathecal fentanyl added to bupivacaine and morphine for cesarean delivery may induce a subtle acute opioid tolerance.
BACKGROUND Previous studies have demonstrated that the addition of intrathecal fentanyl to a spinal anesthetic for cesarean delivery improves intraoperative analgesia. However, intrathecal fentanyl may induce acute tolerance to opioids. The objective of this study was to investigate whether the addition of intrathecal fentanyl to spinal anesthesia with intrathecal morphine increases postoperati...
متن کاملCombined intrathecal morphine and bupivacaine for cesarean section.
The effects of adding 0.2 mg preservative-free morphine sulfate in 0.2 ml solution to hyperbaric spinal bupivacaine were evaluated in a double-blind randomized prospective study of 34 patients undergoing elective repeat cesarean section. In the control patients (n = 17), 0.2 ml saline instead of morphine was added to bupivacaine. The intrathecal morphine significantly improved intra- and postop...
متن کاملEpidural neostigmine produces analgesia but also sedation in women after cesarean delivery.
BACKGROUND Intrathecal neostigmine produces analgesia but also nausea, limiting its utility. In contrast, epidural administration of neostigmine has been suggested to produce postoperative analgesia without nausea in nonpregnant patients. The purpose of this study was to examine the dose range for efficacy and side effects of epidural neostigmine in women at cesarean delivery receiving combined...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Nippon Medical School = Nippon Ika Daigaku zasshi
دوره 70 4 شماره
صفحات -
تاریخ انتشار 2003