Cytokinesis blocked micronucleus (CB-MN) assay for biodosimetry of high dose accidental exposure

نویسندگان

  • K. Shirsath
  • N. Bhat
  • K. Anjaria
  • U. Desai
  • S. Balakrishnan
چکیده

Background: Most of the cytogene c dosimetry, except Premature Chromosome Condensa on assay, saturates at 6 Gy. Present studies are aimed to assess feasibility of simple CB‐MN assay for prescreening of high dose accidental exposures. Materials and Methods: Human peripheral blood lymphocytes from two donors were gamma irradiated to different doses ranging from 0‐15Gy, cultured for 72 h. Cytochalasin‐B was added to the cultures at 44 h. Slides were analyzed for frequency of Mononucleated cells (MNC), ra o of Tri/Quadra nucleated cells, micronuclei ( MN ) yield in MN posi ve cells, mito c bridges and apoptosis. Results: At 5 Gy 67% Mononucleated cells, 0.22% apopto c cells and 1.76% mito c bridges were observed. Micronuclei yield in MN posi ve binucleated cells was found to be 1.43±0.04. At 8Gy 96.63% Mononucleated cells, 22.64% apopto c cells and 3.8% mito c bridges were observed. Micronuclei yield in MN posi ve binucleated cells was found to be 2.18±0.18. At 15 Gy, 99.6% of the cells were Mononucleated and 0.38% was binucleated and MN yield was 2.9 ±0. The total number of MN in MN posi ve cells increases with increasing radia on doses. Conclusion: All the three indicators number of MN in all binucleated cells (BNC) , number of MN /MN posi ve binucleated cells and the nuclear division index (NDI) can serve as good biomarkers for biodosimetry at high doses. Although the frequency of mito c bridges and apopto c bodies increases with dose, there is no consistent difference between various doses. Thus the CBMN + NDI assay can be a biodosimetry method at high doses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cytokinesis blocked micronucleus (CB-MN) assay for biodosimetry of high dose accidental exposure

Background: Most of the cytogenetic dosimetry, except Premature Chromosome Condensation assay, saturates at 6 Gy. Present studies are aimed to assess feasibility of simple CB-MN assay for prescreening of high dose accidental exposures. Materials and Methods: Human peripheral blood lymphocytes from two donors were gamma irradiated to different doses ranging from 0-15Gy, cultured for 72 h. Cytoch...

متن کامل

Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams

Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and Methods: Human peripheral blood lymphocytes were irradiated using proton beams (LET: 34.6 keV μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (CB) micronucleus (MN) assay. To determine th...

متن کامل

Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams

*Corresponding authors: Prof. Tae-Hwan Kim Kim and Chang-Mo Kang, College of Veterinary Medicine, Kyungpook National University, Daegu city, 702-701, Republic of Korea. Fax: +82 53 950 5977 E-mail: [email protected], [email protected] Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and...

متن کامل

Development of a High-Throughput and Miniaturized Cytokinesis-Block Micronucleus Assay for Use as a Biological Dosimetry Population Triage Tool.

Biodosimetry is an essential tool for providing timely assessments of radiation exposure. For a large mass-casualty event involving exposure to ionizing radiation, it is of utmost importance to rapidly provide dose information for medical treatment. The well-established cytokinesis-block micronucleus (CBMN) assay is a validated method for biodosimetry. However, the need for an accelerated sampl...

متن کامل

The micronucleus assay as a biological dosimeter of in vivo ionising radiation exposure.

Biological dosimetry, based on the analysis of micronuclei (MN) in the cytokinesis-block micronucleus (CBMN) assay can be used as an alternative method for scoring dicentric chromosomes in the field of radiation protection. Biological dosimetry or Biodosimetry, is mainly performed, in addition to physical dosimetry, with the aim of individual dose assessment. Many studies have shown that the nu...