Totally biological composite aortic stentless valved conduit for aortic root replacement: 10-year experience
نویسندگان
چکیده
OBJECTIVES To retrospectively analyze the clinical outcome of a totally biological composite stentless aortic valved conduit (No-React® BioConduit) implanted using the Bentall procedure over ten years in a single centre. METHODS Between 27/10/99 and 19/01/08, the No-React® BioConduit composite graft was implanted in 67 patients. Data on these patients were collected from the in-hospital database, from patient notes and from questionnaires. A cohort of patients had 2D-echocardiogram with an average of 4.3 ± 0.45 years post-operatively to evaluate valve function, calcification, and the diameter of the conduit. RESULTS Implantation in 67 patients represented a follow-up of 371.3 patient-year. Males were 60% of the operated population, with a mean age of 67.9 ± 1.3 years (range 34.1-83.8 years), 21 of them below the age of 65. After a mean follow-up of 7.1 ± 0.3 years (range of 2.2-10.5 years), more than 50% of the survivors were in NYHA I/II and more than 60% of the survivors were angina-free (CCS 0). The overall 10-year survival following replacement of the aortic valve and root was 51%. During this period, 88% of patients were free from valved-conduit related complications leading to mortality. Post-operative echocardiography studies showed no evidence of stenosis, dilatation, calcification or thrombosis. Importantly, during the 10-year follow-up period no failures of the valved conduit were reported, suggesting that the tissue of the conduit does not structurally change (histology of one explant showed normal cusp and conduit). CONCLUSIONS The No-React® BioConduit composite stentless aortic valved conduit provides excellent long-term clinical results for aortic root replacement with few prosthesis-related complications in the first post-operative decade.
منابع مشابه
Replacement of the ascending aorta, aortic root, and valve with a novel stentless valved conduit.
PURPOSE Biologic valved-conduit grafts avoid the need for anticoagulation and can exploit the excellent hemodynamic performance of stentless valves. Incorporation of sinuses of Valsalva into the neoaortic root can improve the function of the stentless valves. DESCRIPTION Here we present a novel prefabricated stentless valved conduit incorporating sinuses of Valsalva and describe the technique...
متن کاملPreassembled stentless valved-conduit for the replacement of the ascending aorta and aortic root.
Here we report the early clinical results of a new preassembled stentless valved-conduit incorporating artificial sinuses of Valsalva (BioValsalva). This new composite conduit incorporates a stentless porcine aortic valve (Elan, Vascutek Terumo, UK) suspended within a triple-layered vascular conduit (Triplex, Vascutek Terumo, UK) constructed with sinuses of Valsalva. Between December 2006 and J...
متن کاملLongevity after aortic root replacement: is the mechanically valved conduit really the gold standard for quinquagenarians?
BACKGROUND The choice of the best conduit for root/ascending disease and its impact on longevity remain controversial in quinquagenarians. METHODS AND RESULTS A total of 205 patients (men=155) between 50 and 60 years (mean, 55.7 ± 2.9 years) received either a stentless porcine xenoroot (n=78) or a mechanically valved composite prosthesis (n=127) between February 1998 and July 2011. Of these, ...
متن کاملSevere calcification of a Shelhigh stentless valved conduit.
A 74-year old patient developed severe aortic valve regurgitation 11 years following root replacement using a stentless Shelhigh tube-graft. Computed tomography scan showed a heavily calcified aortic conduit (Fig. 1), although the company claims that detoxification process eliminates residual glutaraldehyde and ensures less calcification in the long term. The patient underwent successful transa...
متن کاملBio-Valsalva prosthesis: 'new' conduit for 'old' patients.
A new bio-prosthetic valved conduit (Bio-Valsalva) has recently been introduced into surgical practice in order to offer a valid option for elderly patients undergoing composite aortic root replacement. The conduit is made up of a stentless porcine valve (elan valve) pre-sewn inside a triple layer Valsalva prosthesis and it is entirely preserved in a glutaraldehyde solution. In our Department, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -