Echocardiographic findings after tricuspid valvectomy.
نویسندگان
چکیده
Resection of the tricuspid valve without prosthetic replacement has successfully been performed in patients with tricuspid valvular endocarditis. Using M-mode, two-dimensional, and Doppler echocardiograms, we studied four patients who underwent tricuspid valvectomy. All patients had previous history of intravenous drug abuse and staphylococcal endocarditis with tricuspid valvular involvement. In all patients, M-mode and two-dimensional echocardiograms showed that the tricuspid valve was absent. The right ventricle was dilated, and the interventricular septum had paradoxical motion in each patient. In each patient the right atrium was dilated, and with each ventricular systole, it expanded and its short axis increased by 20 to 33 percent. This caused shift of the interatrial septum toward the left atrium, with compression of its cavity. Doppler echocardiographic studies showed retrograde flow during systole in the right atrium, inferior vena cava, and hepatic vein. Echocardiographic findings in patients with tricuspid valvectomy correlate with the pathophysiologic findings of this condition.
منابع مشابه
Detection of tricuspid regurgitation with two-dimensional echocardiography and peripheral vein injections.
"Contrast echocardiography", utilizing a two-dimensional ultrasound system and peripheral venous injections, was used for the detection of tricuspid regurgitation in 30 patients. The appearance of contrast in the inferior vena cava and the back and forth movement of contrast across the tricuspid valve were considered evidence for tricuspid regurgitation. Echocardiographic findings were correlat...
متن کاملTricuspid valve fluttering; echocardiographic features of ventricular septal defect.
M-mode echocardiographic features are presented in four patients with membranous ventricular septal defect. The most consistent echo findings in all the patients were the presence of fuzzy, fluttering echoes of the tricuspid valve during systole. More careful echocardiographic evaluation of the tricuspid valve in ventricular septal defect is therefore recommended.
متن کاملCorrelation between echocardiographic and morphological investigations of lesions of the tricuspid valve diagnosed during fetal life.
OBJECTIVE To assess the degree of agreement between the fetal echocardiographic and postmortem examination of hearts from fetuses with severe malformations of the tricuspid valve. DESIGN A retrospective study to analyse echocardiographic recordings and make comparisons with postmortem findings. SETTING Tertiary referral centre for fetal echocardiography. Institute for cardiac morphology. ...
متن کاملTricuspid valve surgery and intraoperative echocardiography: factors affecting survival, clinical outcome, and echocardiographic success.
BACKGROUND The impact of echocardiographic-guided treatment on outcome after tricuspid valve (TV) surgery is not well defined. OBJECTIVES The purpose of this study was to determine clinical and echocardiographic factors associated with adverse outcomes after TV surgery and determine the role of intraoperative echo (IOE) in facilitating successful outcomes after TV surgery. METHODS Four hund...
متن کاملCorrected transposition of great vessels and Ebstein's anomaly of tricuspid valve. Echocardiographic findings.
A case is reported concerning echocardiographic findings in a patient with congenital corrected transposition of the great vessels and Ebstein's anomaly of the tricuspid valve. This presented an unusual opportunity to study atrioventricular valve closure in a patient in whom the Ebstein's malformation involved the systemic atrioventricular valve. The mitral to tricuspid valve closure interval w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 87 5 شماره
صفحات -
تاریخ انتشار 1985