Monitoring change in volume of calcifications in juvenile idiopathic inflammatory myopathy: a pilot study using low dose computed tomography

نویسندگان

  • Maria Ibarra
  • Cynthia Rigsby
  • Gabrielle A. Morgan
  • Christina L. Sammet
  • Chiang-Ching Huang
  • Dong Xu
  • Ira N. Targoff
  • Lauren M. Pachman
چکیده

BACKGROUND Dystrophic calcifications may occur in patients with J uvenile Idiopathic Inflammatory Myopathy (JIIM) as well as other connective tissue and metabolic diseases, but a reliable method of measuring the volume of these calcifications has not been established. The purpose of this study is to determine the feasibility of low dose, limited slice, Computed Tomography (CT) to measure objectively in-situ calcification volumes in patients with JIIM over time. METHODS Ten JIIM patients (eight JDM, two Overlap) with calcifications were prospectively recruited over a 2-year period to undergo two limited, low dose, four-slice CT scans. Calculation of the volume of calcifications used a CT post processing workstation. Additional patient data included: Disease Activity Scores (DAS), Childhood Myositis Assessment Scale (CMAS), myositis specific antibodies (MSA), and the TNFα-308 promoter region A/G polymorphism. Statistical analysis utilized the Pearson correlation coefficient, the paired t-test and descriptive statistics. RESULTS Ten JIIM, mean age 14.54 ± 4.54 years, had a duration of untreated disease of 8.68 ± 5.65 months  MSA status: U1RNP (1), PM-Scl (1), Ro (1, 4 indeterminate), p155/140 (2), MJ (3), Mi-2 indeterminate (1), negative (3). 4/8 JDM (50%) were TNF-α-308 A+. Overall, the calcification volumes tended to decrease from the first to the second CT study by 0.5 cm3 (from 2.79 ± 1.98 cm3 to 2.29 ± 2.25 cm3). The average effective radiation dose was 0.007 ± 0.002, 0.010 ± 0.005, and 0.245 mSv for the upper extremity, lower extremity and chest, respectively (compared to a standard chest x-ray-- 0.02mSV effective dosage). CONCLUSION We conclude: 1) the limited low dose CT technique provides objective data about volume of the calcifications in JIIM; 2) measuring the volume of calcifications in an extremity is associated with minimal radiation exposure; 3) This method may be useful to evaluate the efficacy of therapies for JIIM dystrophic calcification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Characteristics and Outcomes of Juvenile and Adult Dermatomyositis

Dermatomyositis (DM) is an idiopathic inflammatory myopathy with bimodal onset age distribution. The age of onset is between 5-18 yr in juvenile DM and 45-64 yr in adult DM. DM has a distinct clinical manifestation characterized by proximal muscle weakness, skin rash, extramuscular manifestations (joint contracture, dysphagia, cardiac disturbances, pulmonary symptoms, subcutaneous calcification...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

بررسی ارزشمند بودن بیوپسی عضلانی به روش بسته‌ با سوزن در تشخیص بیماریهای التهابی عضله

ABSTRACT To determine the usefulness of a method of percutaneous needle muscle biopsy in patients with suspected idiopathic inflammatory Myopathy. The yield of percutaneous needle muscle biopsy was studied in 15 patients during 1997-2000 who were hospitalized in Hazrat Rasool Akram hospital. A diagnosis of idiopathic inflammatory myopathy was confirmed histopathologically in 8 patients...

متن کامل

Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain

Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...

متن کامل

Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa

Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2016