Determination of carbohydrates in infant milk powders by ultra-performance liquid chromatography with evaporative light scattering detector and BEH HILIC column
نویسندگان
چکیده
The possibility of carbohydrate separation in BEH HILIC (Ethylene Bridged Hybride, Hydrophilic Interaction Liquid Chromatography) column was studied by ultra-performance liquid chromatography (UPLC) with evaporative light scattering detector (ELSD) and mobile phase containing amine compounds as modifiers. The chromatography conditions and ELSD parameters were optimized to separate five typical carbohydrates and applied to analysis of four infant milk powders. The linear ranges of carbohydrate determination were 20-300mg/L for fructose and glucose, 20-250mg/L for sucrose and lactose, and 35-180mg/L for fructo-oligosaccharide. The LODs were 16.4mg/L for fructose and glucose, 17.3mg/L for sucrose, 20.0mg/L for lactose, and 46.7mg/L for fructo-oligosaccharide. Relative standard deviations (RSDs) ranged between 3.45-4.23%, 1.46-4.17%, 4.14-5.60%, 1.39-4.09%, and 2.49-3.61% for fructose, glucose, sucrose, lactose, and fructo-oilgosaccharide, respectively and recoveries ranged between 95.0 and 105.4% Keyword; ultra-performance liquid chromatography, evaporative light scattering detector, HILIC column, carbohydrate, milk powder
منابع مشابه
Determination of Aflatoxins B1 and B2 in Powdered Milk Using Modified Liquid Chromatography Method
Background & Aims: In this study, using a liquid-liquid microextraction method for pre-concentration trace amounts of aflatoxins, the amount of Aflatoxins B1 and B2 in powdered milk was determined. Determination of aflatoxins was done by using high-performance liquid chromatography coupled with fluorescent detector. Method: Samples were extracted by immunoaffinity column (IAC) clean-up, and the...
متن کاملFeasibility of Fraction Collection in HPLC Systems with Evaporative Light Scattering Detector: Analysis of Pectinatella magnifica.
The use of a liquid chromatography (LC) splitter inserted between an HPLC column and an evaporative light scattering detector (ELSD) is described. This paper aims to show the feasibility of using the splitter in an HPLC-ELSD system to fractionate a model mixture of analytes, namely salicin (2-(hydroxymethyl)-phenyl-β-d-glucopyranoside) and glucose. The retention factors and efficiency of the se...
متن کاملDetermination of astragaloside IV in Radix astragali (Astragalus membranaceus var. monghulicus) using high-performance liquid chromatography with evaporative light-scattering detection.
A reverse-phase high-performance liquid chromatographic method is developed for the determination of astragaloside IV, a characteristic constituent in Radix Astragali. Samples are analyzed by means of a reverse-phase column (Zorbax Eclipse XDB C18) using acetonitrile and water under gradient conditions as the mobile phase for 30 min. An evaporative light-scattering detector is used and set at a...
متن کاملSimultaneous Determination of Six Benzodiazepines in Spiked Soft Drinks by High Performance Liquid Chromatography with Ultra Violet Detection (HPLC-UV)
A high performance liquid chromatographic method with ultra violet detection for simultaneous analysis of six benzodiazepines (BZDs) (chlordiazepoxide, diazepam, clonazepam, midazolam , flurazpam and lorazepam) has been developed for forensic screening of adulterated non-alcoholic drinks. Samples were analyzed after a simple procedure for preparation using pH adjustment and filtering. Isocratic...
متن کاملSimultaneous Determination of Six Benzodiazepines in Spiked Soft Drinks by High Performance Liquid Chromatography with Ultra Violet Detection (HPLC-UV)
A high performance liquid chromatographic method with ultra violet detection for simultaneous analysis of six benzodiazepines (BZDs) (chlordiazepoxide, diazepam, clonazepam, midazolam , flurazpam and lorazepam) has been developed for forensic screening of adulterated non-alcoholic drinks. Samples were analyzed after a simple procedure for preparation using pH adjustment and filtering. Isocratic...
متن کامل