An automated method for serum bilirubin determination.
نویسنده
چکیده
A method for the determination of both direct and indirect serum bilirubin on the AutoAnalyzer is described which has a number of advantages over the automated method that is currently recommended. It gives total bilirubin results which are similar to those obtained with the equivalent manual method and direct bilirubin results which are usually about 10% lower.The effect of haemolysis on estimations was investigated. It has little influence on the total, but significantly lowers the direct bilirubin results. Simple methods for the preparation of true bilirubin standards and a stable control serum are described.
منابع مشابه
An Automated Method for the Determination of Serum Bilirubin.
The bilirubin method of Rand and DiPasqua (3), which utilizes a stabilized diazonium salt solution of 2,4 dichloraniline, has been adapted to automatic chemical analysis. Both total bilirubin and “1-mm. reacting” bilirubin can be assayed with good accuracy and precision. Data are presented to show excellent agreement with the manually performed procedure and the procedure of Malloy and Evelyn (...
متن کاملNew automated dye-binding method for serum albumin determination with bromcresol purple.
We describe a new automated dye-binding method for serum albumin determination with bromcresol purple (BCP) that has several advantages over an existing bromcresol green (BCG) method. The continuous-flow method is sensitive, linear, and precise, with negligible sample interaction at an analytical rate of 60 samples per hour. Unlike BCG, BCP did not react with an albumin-free serum globulin prep...
متن کاملAn ultramicro colorimetric method for determination of total and direct serum bilirubin.
A simple reproducible method for the ultramicro determination of total and direct serum bilirubin is presented. This method provides a greater sensitivity than that obtained with other colorimetric ultramicro procedures. Total bilirubin values agree with those obtained with the macro Malloy-Evelyn procedure, but direct-reading bilirubin values were significantly higher with the presented method.
متن کاملEffect of bilirubin and lipemia on an automated method for serum cholesterol.
A simple automated procedure for total serum cholesterol, employing a stable Liebermann-Burchard reagent, was tested. The method has good precision, and results agree well with extraction methods for total cholesterol on normal serums. Serum samples with elevated bilirubin levels gave cholesterol values which were too high and which could not always be corrected for. Lipemic serums in some inst...
متن کاملOxidation markedly reduces bilirubin interference in the Jaffé creatinine assay.
Bilirubin causes underestimation of serum creatinine in the Jaffé alkaline picrate assay. We report an approach for preventing bilirubin interference by pretreating serum samples with peroxidase and H2O2. The dissociation of bilirubin from albumin and its subsequent oxidation markedly reduces the bilirubin interference and enables accurate determination of creatinine concentrations by the Jaffé...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 21 2 شماره
صفحات -
تاریخ انتشار 1968