Quaternion Atomic Phase Magnification for 2D and 3D Motion

نویسندگان

  • Eduardo Ulises Moya-Sánchez
  • Marcela Bonell
  • Gustavo Torres
  • Eduardo Vázquez-Santacruz
چکیده

The phase computation is used in many applications of signal and image processing such as edge, line, symmetry detection, image analysis and recently to show small motion or color changes. Eulerian video processing allows to show small color changes and motions invisibles to the naked eye. Eulerian motion magnification, was modify using the phase and the Riesz pyramid in order to reduce the noise amplification. In this work we introduced a novel phase magnification approach based on a infinitely differentiable unique compact supported window, an atomic function. Another contribution of our work was apply our quaternion phase and Eulerian magnification to 3D motion, which has not been reported so far, we propose to use simple projections of conformal algebra in order to do the magnification at any plane of the 3D space. We compare the phase (Riesz Pyramids), with the atomic Riesz pyramid, in our comparation our atomic pyramid Riesz preserves more information than the phase Riesz approximation, besides our approach is slower by 2.5 times. Finally, we compare method and the linear magnification (Laplace Pyramid) in terms of the Signal to Noise Ratio (SNR). We found that the phase magnifications has better response to noise than the linear method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of respiratory motion on dose distribution of 3D-CRT and IMRT- A simulation study

Background: 3DCRT (three-dimensional conformal radiotherapy) and IMRT (intensity-modulated radiotherapy) has provided us with tools to delineate the radiation dose distribution of tumor targets. However, the precision of radiation can be compromised by respiratory motion, which usually limits the geometric and dosimetric accuracy of radiotherapy. The purpose of this study is to evaluate the imp...

متن کامل

Designing, validation, and reliability assessment of software to acquire kinematics parameters of motion by image processing

Motion analysis systems are useful and effective equipment in biomechanics research. Unfortunately these systems are available for few researchers because these are expensive equipment. The aim of this study was to design and validation of a practical and inexpensive software, to determine the exact markers position in space and compute the kinematic of movement. In designing the software, the ...

متن کامل

Viscous Models Comparison in Water Impact of Twin 2D Falling Wedges Simulation by Different Numerical Solvers

In this paper, symmetric water entry of twin wedges is investigated for deadrise angle of 30 degree. Three numerical simulation of a symmetric impact, considering rigid body dynamic equations of motion in two-phase flow is presented. The two-phase flow around the wedges is solved by Finite Element based on Finite Volume method (FEM-FVM) which is used in conjunction with Volume of Fluid (VOF) sc...

متن کامل

Traveling Wave Solutions of 3D Fractionalized MHD Newtonian Fluid in Porous Medium with Heat Transfer

In the present paper, we get exact solutions of Magnetohydrodynamic (MHD) of the fractionalized three-dimensional flow of Newtonian fluid with porous and heat transfer through the traveling wave parameter. The governing equations are produced dependent on established Navier-stokes equations which can be diminished to ordinary differential equation by wave parameter ξ=ax+by+nz+Utα/Γ(α...

متن کامل

Performance evaluation of gated volumetric modulated arc therapy

Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Research in Computing Science

دوره 118  شماره 

صفحات  -

تاریخ انتشار 2016