In vivo magnetic resonance imaging of coronary thrombosis using a fibrin-binding molecular magnetic resonance contrast agent.
نویسندگان
چکیده
BACKGROUND The advent of fibrin-binding molecular magnetic resonance (MR) contrast agents and advances in coronary MRI techniques offers the potential for direct imaging of coronary thrombosis. We tested the feasibility of this approach using a gadolinium (Gd)-based fibrin-binding contrast agent, EP-2104R (EPIX Medical Inc), in a swine model of coronary thrombus and in-stent thrombosis. METHODS AND RESULTS Ex vivo and in vivo sensitivity of coronary MR thrombus imaging was tested by use of intracoronarily delivered Gd-DTPA-labeled fibrinogen thrombi (n=6). After successful demonstration, in-stent coronary thrombosis was induced by x-ray-guided placement of thrombogenic-coated, MR-lucent stents (n=5). After stent placement, 60 micromol of EP-2104R was injected via the left main coronary artery. Free-breathing, navigator-gated 3D coronary MR angiography and thrombus imaging were performed (1) before and after stent placement and (2) before and after EP-2104R. Thrombi were confirmed by x-ray angiography and autopsy. Fibrinogen thrombi: 5 of 6 intracoronarily delivered Gd-labeled fibrinogen clots (approximately 250 micromol/L Gd) were visible on MRI and subsequently confirmed by x-ray angiography. In-stent thrombi: in-stent thrombosis was observed in all stents after EP-2104R. Four of 5 thrombi were confirmed by x-ray angiography. Chemical analysis of 2 thrombi demonstrated 99 to 147 micromol/L Gd. CONCLUSIONS We demonstrate the feasibility of MRI of coronary thrombus and in-stent thrombosis using a novel fibrin-binding molecular MR contrast agent. Potential applications include detection of coronary in-stent thrombosis or thrombus burden in patients with acute coronary syndromes.
منابع مشابه
A New Theranostic System Based on Gd2O3 NPs coated Polycyclodextrin Functionalized Glucose for Molecular Magnetic Resonance Imaging (MMRI).
Introduction: Recent advances in nanoscience and biomedicine have attracted tremendous attention over the past decade to design and construct multifunctional nanoparticles that combine targeting, therapeutic, and diagnostic functions with a single platform to overcome the problems of conventional techniques for diagnosis and therapy with minimal toxicity. Materials ...
متن کاملA New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite
Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...
متن کاملAnalytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کاملFe3O4@Ag Nanoprobe for Detection of Ovarian Cancer Cell Line Using Magnetic Resonance Imaging
Background and Aims: Magnetic resonance imaging (MRI) plays an essential role in molecular imaging by delivering the contrast agent into targeted cells. The aim of this study was to evaluate the use of magnetic nanoparticles containing iron oxide and silver (Fe3O4@Ag core-shell nanoprobe) as a contrast agent for the detection of ovarian cancer cell line ovcar-3. Materials and Methods: Co-preci...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 110 11 شماره
صفحات -
تاریخ انتشار 2004