In this paper, we study the no-load behavior of a lightweight piezo-composite curved actuator (LIPCA) subjected to voltage and charge control. First, we examine the effect of hysteresis and creep when the actuator is voltage controlled at a slow scan speed. The experimental results show that creep increases the displacement hysteresis by over 25% when scanning at 1/60 Hz. Afterwards, we discuss the design and implementation of a charge-feedback circuit to control the displacement of the actuator. The hysteresis curves between voltageand charge-control modes are compared for the scan frequencies of 1 and 5 Hz. The results show that charge control (compared to voltage control) of a LIPCA device exhibits significantly less hysteresis – over 80% less.
منابع مشابه
ADAPTIVE FUZZY OUTPUT FEEDBACK TRACKING CONTROL FOR A CLASS OF NONLINEAR TIME-VARYING DELAY SYSTEMS WITH UNKNOWN BACKLASH-LIKE HYSTERESIS
This paper considers the problem of adaptive output feedback tracking control for a class of nonstrict-feedback nonlinear systems with unknown time-varying delays and unknown backlash-like hysteresis. Fuzzy logic systems are used to estimate the unknown nonlinear functions. Based on the Lyapunov–Krasovskii method, the control scheme is constructed by using the backstepping and adaptive techniqu...
متن کاملThe Design of a High-voltage Charge-feedback Piezoamplifier
This paper presents the design and development of a high-voltage charge-feedback amplifier for controlling the displacement of piezoelectric devices to account for hysteresis. In particular, we discuss the details of the design and characterize the performance of the amplifier in terms of output power, bandwidth, and reduction of hysteresis for an experimental piezoactuator. We note that charge...
متن کاملPOLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE
Polarization for Au/Pb(Zr Ti )O /YBa Cu O ferroelectric capacitor has been studied and measured by pulse method. A sequence of pulses with amplitudes varying from 0 to 10 volts in 2 volt steps is applied and a conventional polarization curve is obtained by integrating the charge flow from the polarization switching induced by the voltage ramp. A value of 25?C/cm2 is measured for the satur...
متن کاملCharge drives for scanning probe microscope positioning stages.
Due to hysteresis exhibited by piezoelectric actuators, positioning stages in scanning probe microscopes require sensor-based closed-loop control. Although closed-loop control is effective at eliminating non-linearity at low scan speeds, the bandwidth compared to open loop is severely reduced. In addition, sensor noise significantly degrades achievable resolution in closed loop. In this work, c...
متن کاملTracking control of piezoelectric actuator system using inverse hysteresis model
The intrinsic hysteresis behavior of piezoelectric material limits the tracking control accuracy of the actuators. This paper describes a tracking control method for piezoelectric actuators based on the combination of feedforward and feedback loops. The hysteresis of piezoelectric actuators is linearized in feedforward loop with an inverse hysteresis model based on a neural network. The number ...