Obstructive shadow of ribs imaged on the axial transverse tomogram of the chest.

نویسنده

  • A Takeuchi
چکیده

In order to take an axial transverse tomogram having few obstructive shadows, the phantom and human experiment were perfomed and studied. Thorax cage phantom composed of ribs made of lead wire was laid on the table of axial transverse tomograph of horizontal type and the axial transverse tomograms were taken with the central X-ray of caudalocranial or craniacaudal direction with the range of rotation of 180°, rotating from the right, front and left side of the body. Obstructive shadow arose mostly when projected caudalocranial direction of cent ral X-ray, while fairly few when taken with craniocaudal direction. With exposure of full rotation of 360°, the obstructive shadow was more fa int than the above two. This was confirmed also with the human experiment. When the axial transverse tomogram of the chest is taken, the obstructive shadows of the rib are imaged at times on the lung field and desturb correct interpretation. In order to take tomograms having few such shadows the studies of the optimal range of rotation of the X-ray tube around the human body and the angle of the central X-ray to the ribs at the tomography were made with phantom and human body experiments. 1. EXPERIMENTS WITH A PHANTOM For this experiment the presentaions of the problem are as follows: I) is there any difference of the appearance of obstructive shadows between the tomography conducted with the range of rotation of 180° and that of 360°? 2) does the angle of inclination of the ribs to the horizon influence on the grades of appearance of these shadows? An axial transverse tomograph of the erect type (Shimadzu) 1 >2> was used for the experiments, with the phantom to be radiographed placed on a rotating table in the erect position. The distance of X-ray tube, phantom and film were so arranged as to produce an X-ray image 1.27 times the actual size. The fr'J Ji'J llB Received for publication February 13, 1968.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rib Abnormalities Investigated by Computed Tomography: A Report on Common and Uncommon Cases

Purpose: Rib anomalies include numerical and structural categories. This study investigates the costal abnormalities by computed tomography scan in an Iranian population. Methods: In a retrospective study, 400 Chest CT scans (225 (56.2%) male, and 175 (43.8%) female) aging from 18 to 89 were investigated for one year (2020 to 2021). Images were carefully observed and various abnormalities suc...

متن کامل

The anatomy of the brachial plexus as displayed by magnetic resonance imaging: technique and application.

Full field of view coronal chest magnetic resonance imaging (MRI) routinely displays bilateral images of the brachial plexus, surface anatomy, and anatomic structures. Eighty patients had chest radiographs correlated with surgery for thoracic outlet syndrome. The PA chest film findings correlated with the surgical findings: smaller thoracic inlet on the concave side of the cervicothoracic spine...

متن کامل

Color isodose curve plotter applied to beam focus radiography.

An apparatus was constructed to facilitate superimposition of the beam focus radiogram upon the axial transverse tomogram, in order to guide subsequent radia tion therapy more accurately. The apparatus automatically draws six isodose curves in three colors, by plotting the relative doses of the beam focus radiogram. In addition, the isodose chart was made at the same magnification as that of th...

متن کامل

Buckling Analysis of Composite Lattice Cylindrical Shells with Ribs Defects

In this paper, the buckling behavior of a composite lattice cylindrical shell is studied and effects of rib defects on the distribution of stress field and buckling response of the shell is investigated. A three dimensional finite element buckling analysis of the lattice shell is carried out using ANSYS suit of program. Geometrical data and material properties of the shell are obtained from the...

متن کامل

[Radiologic-anatomic correlation of thoracic vertebrae and rib shadows in chest digital radiograph].

The purpose of this study was to provide an introduction to parsing the radiologic appearance of thoracic vertebrae and ribs. In the study, the radiologic-anatomic correlation technique was applied to promote further understanding of normal chest radiographs. The thoracic vertebrae and ribs of chest radiographs were compared with each macroscopic radiologic and computed tomography (CT) image. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nagoya journal of medical science

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 1969