Time-based on-line preconcentration cold vapour generation procedure for ultra-trace mercury determination with inductively coupled plasma atomic emission spectrometry.
نویسندگان
چکیده
A time-based sequential dispensing on-line column preconcentration procedure for mercury determination at trace levels by cold vapour generation inductively coupled plasma atomic emission spectrometry (CV-ICP-AES), by means of a unified module of a preconcentration column and a gas-liquid separator (PCGLS) is described. The complex of mercury formed on-line with ammonium pyrrolidine dithiocarbamate (APDC) is retained on the surface of the hydrophobic poly(tetrafluoroethylene) (PTFE) turnings, which are packed into the lower compartment of the PCGLS. Subsequently, mercury vapour is generated directly on the PTFE turnings by reductant SnCl(2) and separated from the liquid mixture via the PCGLS by argon purge gas. The outlet of the PCGLS is connected directly to the torch adapter of the plasma without the normal spray chamber and nebulizer. With 60-s preconcentration time and 12.0 mL min(-1) sample flow rate, the sampling frequency is 30 h(-1). The calibration curve is linear over the concentration range 0.02-5.0 microg L(-1), the detection limit ( c(L)) is 0.01 microg L(-1) and the relative standard deviation ( s(r)) is 3.1% at the 1.0 microg L(-1) level. The proposed method was evaluated by analysis of BCR CRM 278 (Mytilus Edulis) reference material and applied to the determination of total mercury in digested urine, blood and hair samples.
منابع مشابه
Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
متن کاملOn-line preconcentration of mercury by sorption on an anion-exchange resin loaded with 1,5-bis[(2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide and determination by cold-vapour inductively coupled plasma atomic emission
1,5-Bis[(2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex) has been used for the on-line preconcentration of mercury from biological samples and waters prior to its determination by inductively coupled plasma atomic emission spectroscopy. The metal was eluted from the column using a solution of 2 M HNO3 and mixed on-line with SnCl2. ...
متن کاملApplication of iminodiacetate chelating resin muromac A-1 in on-line preconcentration and inductively coupled plasma optical emission spectroscopy determination of trace elements in natural waters
On-line system incorporating a microcolumn of Muromac A-1 resin was used for the developing of method for preconcentration of trace elements followed by inductively coupled plasma (ICP) atomic emission spectrometry determination. A chelating type ion exchange resin has been characterized regarding the sorption and subsequent elution of 24 elements, aiming to their preconcentration from water sa...
متن کاملReview of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملReview of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 379 5-6 شماره
صفحات -
تاریخ انتشار 2004