Noninvasive assessment of retinal function in rats using multifocal electroretinography.
نویسندگان
چکیده
PURPOSE To assess the applicability of multifocal electroretinograms (mfERGs) for evaluation of function in this small-eyed animal with a rod-dominant retina that is often used to model retinal diseases. METHODS Noninvasive monocular mfERGs were recorded in anesthetized albino (Sprague-Dawley) and pigmented (Long Evans) rats. Achromatic stimuli subtending a 49 degrees by 53 degrees field consisted of 61 hexagons that were generated and presented (at varying rates and luminances) using a Visual Evoked Response Imaging System (VERIS; EDI, San Mateo, CA). The VERIS also was used to calculate individual responses and for analysis. RESULTS mfERGs were recorded from pigmented and albino rats by slowing the rate of stimulus presentation to allow for the slow recovery time of the rod system. In each rat strain, responses varied systematically with changes in stimulus parameters. Peak response amplitude increased as the rate of stimulation was slowed and as stimulus luminance was increased. Response latency decreased as stimulus intensity was increased. The local nature of the response was assessed by several independent measures. CONCLUSIONS The present work demonstrated the feasibility and limitations of using mfERG to assess topographical changes in the rat retina. It showed that despite the problems of the unavoidable self-adapting nature of the stimulus, the small eye of the animal, and the high potential for light scatter within the retina, multifocal responses with a good signal-to-noise ratio can be obtained from the rat.
منابع مشابه
The Role of Multifocal Electroretinography in the Assessment of Drug-Induced Retinopathy: A Review of the Literature.
Multifocal electroretinography (mfERG) is an objective, noninvasive examination for the assessment of visual function. It enables the stimulation of multiple retinal areas simultaneously and recording of each response independently, providing a topographic measure of retinal electrophysiological activity in the central 40-50° of the retina. A clinical application of mfERG represents the assessm...
متن کاملThe use of multifocal electroretinography in the assessment of retinal toxicity caused by pharmacological agents
Multifocal electroretinography (mfERG) was developed by Sutter and Tran1 and has since revolutionized objective functional assessment of retinal diseases. In contrast to full-field electroretinography (ERG), which measures the electrical activity of the entire retina, mfERG allows simultaneous measurements of multiple responses at different retinal locations, thus enabling topographic mapping o...
متن کاملPotential diagnostic dilemmas using the multifocal electroretinogram in intermittent exotropia
Multifocal electroretinography (mfERG) is a valuable technique in assessing macular function in retinal disease objectively as it provides spatial information. Altered responses give an estimate of the extent of central retinal dysfunction. Fixation is known to be an important technical factor in mfERG recording. We present findings in a patient with asymptomatic intermittent exotropia that rei...
متن کاملAssessment of macular function by multifocal electroretinography following epiretinal membrane surgery with internal limiting membrane peeling
The aim of the current study was to evaluate macular function before and after surgery for idiopathic epiretinal membranes with internal limiting membrane (ILM) peeling by means of multifocal electroretinography (ERG). Eighteen eyes of 18 patients who underwent vitrectomy with ILM removal were included. Best corrected visual acuity, optical coherence tomography (OCT), and multifocal electroreti...
متن کاملChlorogenic Acid Supplementation Improves Multifocal Electroretinography in Patients with Retinitis Pigmentosa
To evaluate the effect of chlorogenic acid supplementation in patients with retinitis pigmentosa, we evaluated objective change in visual function with multifocal electroretinography, along with visual acuity, visual field, standard electroretinography, and contrast sensitivity. Eighteen patients diagnosed with retinitis pigmentosa were enrolled in this prospective, non-comparative, single-arm ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 41 2 شماره
صفحات -