Fluctuation of adenosine concentration by modes of intravenous infusion based on mathematical simulation and experiments.

نویسندگان

  • Kenichi Nakajima
  • Junichi Taki
  • Tatsuya Yoneyama
  • Makoto Fukuoka
  • Daiki Kayano
  • Norihisa Tonami
چکیده

OBJECTIVE Adenosine, which has been used for a myocardial perfusion scan, shows rapid clearance from blood because of its short half-life of <10 seconds. This simulation study evaluates influences of modes of radionuclide injection on ventricular adenosine concentration when one intravenous injection line is used. METHODS Assuming that radionuclide injection is a unit impulse, time-activity curves were measured in the left ventricle (LV) and fitted by a gamma function. Typical patterns of concentration fluctuation when adenosine infusion was temporarily modified were calculated by the convolution integral of input function and unit impulse response. Variation of concentration was measured by experiments using continuous 99mTc injection and co-infusion of water via a three-way stopcock. Modes of co-infusion with various infusion speeds and volumes were examined. RESULTS Intermission of adenosine infusion and rapid displacement by radionuclide co-injection significantly influenced the adenosine concentration in LV. Intermission of adenosine infusion for 2 seconds caused a 15% decrease in the adenosine concentration in the left ventricle. When a square-shaped input was assumed, a three-fold higher concentration of adenosine for 3 seconds created by radionuclide injection resulted in a +42% increase in the LV concentration. Based on a measured input function, radionuclide injection using three-way stopcock through one route caused a two- to three-fold increase in the steady concentration in the vein just after injection. When 0.5 ml of radionuclide was slowly co-injected, with three ways opened, it caused a relatively low fluctuation, creating a +34% to -47% change in concentration of LV. A flush of radionuclide with physiological saline significantly increased the adenosine concentration in LV, when short half-lives were assumed. CONCLUSION An intravenous adenosine and radiopharmaceutical injection in the same line is feasible. However, the fluctuation of concentration depends significantly on the mode of injection. To minimize the fluctuation, a slow injection of a small volume of a myocardial imaging agent via a co-injection route, with three ways opened, is recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of short term intravenous infusion of a soybean based lipid emulsion on some blood constituents in sheep: A preliminary study

To evaluate the effect of intravenous infusion of a soybean based lipid emulsion (Lipovenoes 10%) on some blood constituents in sheep, a replicated 2 × 2 Latin square design experiment was conducted in four clinically healthy ewes. Lipid emulsion (LE group) or normal saline (NS group) was infused intravenously at a rate of 0.025 mL kg-1 per min for 6 hr and the concentrations of bloo...

متن کامل

Evaluation of Intravenous Lidocaine Overdose in Chickens (Gallus domesticus)

Objective- To evaluate the total toxic dose of lidocaine and serum lidocaine concentrations resulting in clinical signs of toxicity in chickens. Design- Experimental study Animals- Eight healthy, female, 55-week-old chickens (Lohman breed) weighing 1.45 ± 0.17 kg (mean ± SD) Procedure- A loading dose of 2% lidocaine (4 mg/kg) was administered IV, followed by a constant-rate infusion at a dose o...

متن کامل

Heparin Resistance During and Post-Intravenous Nitroglycerin Infusion

      Nitroglycerin has been reported to reduce activated partial thromboplastin time (aPTT) values in patients treated with concurrent heparin and nitroglycerin. However, studies have yielded conflicting results. To determine whether intravenous nitroglycerin alters the anticoagulant effect of heparin, we prospectively evaluated twenty patients admitted for coronary angioplasty by measurin...

متن کامل

Performance Evaluation of Ceramic Membrane on Ultrafiltration and Diafiltration Modes for Efficient Recovery of Whey Protein

The recovery of high-quality, valuable end products from cheese whey is a very important industrial process. The aim of this study is to improve the recovered protein content of concentrate stream in cheese whey. The experiments were conducted by using ceramic ultrafiltration (UF) membrane followed by diafiltration (DF) process with a 15kDa molecular weight cut-off (MWCO). The volume concentrat...

متن کامل

عوارض ناشی از تزریق ایمونوگلوبولین وریدی در بیماران با نقص ایمنی اولیه

Background and Purpose: Intravenous immunoglobulin is used for primary immunodeficiency disorders. There have been some reports that intravenous immunoglobulin causes side effects. The aim of this study was to investigate intravenous immunoglobulin side effects in immunodeficiency patients. Materials and Methods: The study utilized the data of 29 primary immunodeficiency patients that were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 20 7  شماره 

صفحات  -

تاریخ انتشار 2006