Reproducibility of Computer-Quantified Carotid Plaque Echogenicity
نویسندگان
چکیده
Background and Purpose—We sought to assess the reproducibility, interobserver variability, and application to clinical studies of a new method for the quantitative assessment of carotid plaque echogenicity. Methods—Carotid plaques were scanned with the use of ultrasound, and their images were stored in a computer. They were normalized by assigning certain gray values to blood and adventitia, and the gray scale median (GSM) was used to quantify their echogenicity. The variability between storage media, between degrees of magnification, and between probes was assessed. The method was applied to 232 asymptomatic carotid plaques causing 60% to 99% stenosis in relation to the presence of ipsilateral CT-demonstrated brain infarcts. In all parts of the study the plaque GSM was measured before and after normalization to evaluate its effect. Interobserver agreement for the scanning process was assessed. Results—The GSM mean difference before and after normalization for variability studies of storage media, degrees of magnification, and probes was 214.5 and 20.12, 2.24 and 1.68, and 28.3 and 20.7, respectively. The median GSM of plaques associated with ipsilateral nonlacunar silent CT-demonstrated brain infarcts was 14, and that of plaques that were not so associated was 30 (P50.003). The interobserver GSM difference was 20.05 (95% CI, 21.7 to 1.6). Conclusions—Our method decreases the variability between storage media and between probes but not the variability between degrees of magnification. It separates echomorphologically the carotid plaques associated with silent nonlacunar CT-demonstrated brain infarcts from plaques that are not so associated. (Stroke. 2000;31:2189-2196.)
منابع مشابه
Observer performance in characterization of carotid plaque texture and surface characteristics with 3D versus 2D ultrasound
OBJECTIVE To determine the reproducibility of three-dimensional (3D) ultrasound (US) over two-dimensional (2D) US in characterizing atherosclerotic carotid plaques using inter- and intra-observer agreement metrics. METHODS A Total of 51 patients with 105 carotid artery plaques were screened using 3D and 2D US probes attached to the same US scanner. Two independent observers characterized the ...
متن کاملAtheromatous plaque: quantitative analysis of the echogenicity of different layers.
INTRODUCTION AND OBJECTIVES Echographic studies of the composition of atheromatous plaque make use of the median gray level, which provides an overall measure of echogenicity. We propose adding an additional dimension to this approach by dividing the lesion into layers and generating a curve that shows the variation in echolucency with depth. METHODS Femoral and carotid plaque in asymptomatic...
متن کاملHigher levels of interleukin-6 are associated with lower echogenicity of carotid artery plaques.
BACKGROUND AND PURPOSE Echo-lucent carotid plaques can be fragile and vulnerable to rupture, representing a risk factor for ischemic stroke. Given the studies showing that elevated levels of circulating inflammatory markers are predictive of cardiovascular events, we sought to determine whether higher levels of serum interleukin-6 (IL-6) and high-sensitivity C-reactive protein (hsCRP) are assoc...
متن کاملShear wave elastography imaging of carotid plaques: feasible, reproducible and of clinical potential
BACKGROUND Shear Wave Elastography (SWE) imaging is a novel ultrasound technique for quantifying tissue elasticity. Studies have demonstrated that SWE is able to differentiate between diseased and normal tissue in a wide range clinical applications. However its applicability to atherosclerotic carotid disease has not been established. The aim of this study was to assess the feasibility and pote...
متن کاملUltrasound Assessment of Carotid Plaque Echogenicity Response to Statin Therapy: A Systematic Review and Meta-Analysis
OBJECTIVE To evaluate in a systematic review and meta-analysis model the effect of statin therapy on carotid plaque echogenicity assessed by ultrasound. METHODS We have systematically searched electronic databases (PubMed, MEDLINE, EMBASE and Cochrane Center Register) up to April, 2015, for studies evaluating the effect of statins on plaque echogenicity. Two researchers independently determin...
متن کامل