The use of a pressure manometer enhances student physiotherapists' performance during manual hyperinflation.
نویسندگان
چکیده
The purpose of this study was to determine the effect of using a pressure manometer on the delivery of target airway pressures during manual hyperinflation by student physiotherapists in the laboratory and clinical environments. Manual hyperinflations were delivered under control and feedback conditions where the feedback condition involved manual hyperinflation with a pressure manometer. Compared with control conditions, the availability of a manometer significantly decreased the mean absolute error (9.5 +/- 0.9 cm H2O to 1.4 +/- 0.2 cm H2O) and mean variable error (2.2 +/- 0.3 cm H2O to 1.3 +/- 0.1cm H2O) of peak airway pressures during manual hyperinflation. In addition, the availability of a manometer negated the influence of environment on accuracy. Therefore, the availability of a pressure manometer provided an effective clinical tool that was easily used to provide feedback regarding the peak airway pressures delivered during manual hyperinflation.
منابع مشابه
Pattern of ventilation during manual hyperinflation performed by physiotherapists.
Summary The aim of this prospective observational study was to document patterns of ventilation during manual hyperinflation by physiotherapists. Manual hyperinflation with a Mapleson-F system was performed on the same patients on two consecutive days. Patterns of ventilation were recorded using a heated pneumotachometer, pressure transducer and custom designed data acquisition and analysis sys...
متن کاملPRI 6(2) crc
Background and Purpose: The present study aimed to evaluate the consistency with which physiotherapists apply manual hyperinflation to a test lung using the AirViva-2 or Mapleson-B resuscitation circuit, and their ability to modify the technique as pulmonary characteristics change. Method: A quasi-experimental, randomized, repeatedmeasures design was used to study 16 volunteer physiotherapists ...
متن کاملThe effect on expiratory flow rate of maintaining bag compression during manual hyperinflation.
Operator performance during the expiratory phase of manual hyperinflation appears to vary between physiotherapists for Mapleson-B or C circuits. Some physiotherapists release the valve but maintain compression of the bag, whereas others release both the valve and the bag. The effect of this difference on peak expiratory flow rate (PEFR) has not been reported. The aim of this study was to docume...
متن کاملEffects of Manual Lung Hyperinflation Using Rebreathing Bags on Cardiorespiratory Parameters in Intubated Adults
Manual hyperinflation is a technique that is commonly used by physiotherapists to provide a greater than baseline tidal volume to the lungs of mechanically ventilated patients. The use of this technique is based more on clinical experience than on scientific evidence as the physiological effects of manual hyperinflation are uncertain. This review uses evidence-based principles to investigate th...
متن کاملEffect of Manual Hyperinflation on Arterial Oxygenation in Paediatric Patients with Upper Lobe Collapse after Cardiac Surgery
Lung hyperinflation is a technique used by physiotherapists to mobilize and remove excess bronchial secretions, reinflate areas of pulmonary collapse and improve oxygenation. To assess the efficacy of manual hyperinflation in improving arterial oxygenation (PaO2) of paediatric patients with upper lobe lung collapse after cardiac surgery. 18 paediatric patients who had undergone heart surgery an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Australian journal of physiotherapy
دوره 47 2 شماره
صفحات -
تاریخ انتشار 2001