Independent and incremental role of quantitative right ventricular evaluation for the prediction of right ventricular failure after left ventricular assist device implantation.

نویسندگان

  • Andrew D M Grant
  • Nicholas G Smedira
  • Randall C Starling
  • Thomas H Marwick
چکیده

OBJECTIVES This study sought to determine the utility of quantitation of right ventricular (RV) function in predicting RV failure in patients undergoing left ventricular assist device (LVAD) implantation. BACKGROUND Clinical evaluation alone seems insufficient for predicting RV failure, an important cause of morbidity and mortality after LVAD implantation. METHODS Clinical, hemodynamic, and echocardiographic data were collected on 117 patients undergoing LVAD implantation. Standard pre-procedural echocardiographic RV measurements were supplemented by velocity vector imaging of RV free wall longitudinal strain. RV failure was defined as the need for placement of an RV assist device, or the use of inotropic agents for >14 days. Receiver operating characteristic curves were derived, with resampling to generate valid estimates of prediction accuracy. A net reclassification index was calculated for comparison of risk scores. RESULTS RV failure occurred in 47 of 117 patients (40%). There was a significant difference in peak strain between patients with and without RV failure (-9.0% vs. -12.2%; p < 0.01). A peak strain cutoff of -9.6% predicted RV failure with 76% specificity and 68% sensitivity. In a multivariate logistic regression analysis including variables from the established Michigan RV risk score, peak strain remained an independent predictor of RV failure. RV strain was incremental to the Michigan risk score as a predictor of RV failure (area under the receiver operating characteristic curve: 0.77 vs. 0.66; p < 0.01). The net reclassification index with strain was +10.4%. CONCLUSIONS Reduced RV free wall peak longitudinal strain was associated with an increased risk for RV failure among patients undergoing LVAD implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.

OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were exami...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 60 6  شماره 

صفحات  -

تاریخ انتشار 2012