Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation
نویسندگان
چکیده
The intra-aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre-, intra-, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi-recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra-aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits.
منابع مشابه
Reversed intracranial blood flow in patients with an intra-aortic balloon pump.
As a preliminary investigation into the cerebral effects of mechanical cardiac assist devices, using transcranial Doppler ultrasonography I examined the basal cerebral arteries in three patients placed on an intra-aortic balloon pump. Unassisted systoles had normal blood velocities and waveforms. When the pump was in use, diastolic blood velocity during balloon inflation increased. As the ballo...
متن کاملLeft ventricular function during balloon dilatation of the aortic valve in elderly patients: a blind study of echocardiograms.
Subcostal echocardiography of the left ventricle was continuously recorded during balloon dilatation of the aortic valve in ten consecutive elderly patients. Left ventricular wall motion decreased gradually during a minute of maintained complete balloon inflation. Blind analysis of M mode echocardiograms showed a significant reduction in fractional shortening. Deflation of the balloon resulted ...
متن کاملCoronary and microvascular physiology during intra-aortic balloon counterpulsation.
OBJECTIVES This study sought to identify the effect of coronary autoregulation on myocardial perfusion during intra-aortic balloon pump (IABP) therapy. BACKGROUND IABP is the most commonly used circulatory support device, although its efficacy in certain scenarios has been questioned. The impact of alterations in microvascular function on IABP efficacy has not previously been evaluated in hum...
متن کاملDoes conventional intra-aortic balloon pump trigger timing produce optimal hemodynamic effects in vivo?
PURPOSE The intra-aortic balloon pump (IABP) provides circulatory support through counterpulsation. The hemodynamic effects of the IABP may vary with assisting frequency and depend on IAB inflation/deflation timing. We aimed to assess in vivo the IABP benefits on coronary, aortic, and left ventricular hemodynamics at different assistance frequencies and trigger timings. METHODS Six healthy, a...
متن کاملO-32: Pain Experienced during Sonohysterography :Cervical to Uterine Catheter Placement
Background: The aim of this study is to evaluate whether the location of the balloon placement into either the cervical canal or uterine cavity during sonohysterography can affect the intensity of pain. Materials and Methods: A total of 300 infertile women undergoing sonohysterography were randomized to intracervical or intrauterine balloon placement. The examination was scheduled in the early ...
متن کامل