18F-FDG PET in pregnancy and fetal radiation dose estimates.

نویسندگان

  • Amol M Takalkar
  • Alok Khandelwal
  • Stephen Lokitz
  • David L Lilien
  • Michael G Stabin
چکیده

UNLABELLED The purpose of this study was to estimate the fetal radiation exposure resulting from (18)F-FDG PET procedures performed in pregnant patients with malignancies. METHODS Five pregnant patients with a biopsy-proven diagnosis of malignancy who underwent (18)F-FDG PET studies were retrospectively reviewed. All patients underwent PET-only studies (and not PET/CT studies) with a reduced (18)F-FDG dose (except for 1 patient who had a negative pregnancy test immediately before the (18)F-FDG PET procedure but was confirmed to be pregnant a few weeks later), including vigorous hydration and diuresis to minimize radiation exposure to the fetus. One patient underwent (18)F-FDG PET twice during her pregnancy (in the second and third trimesters). Fetal radiation dose was independently assessed for each patient, and an analysis was made of fetal radiation doses using the measurements of activity in the fetuses at various stages of pregnancy. RESULTS Six (18)F-FDG PET studies in 5 pregnant patients were analyzed. The (18)F-FDG PET scans were obtained in early pregnancy (n = 1), the second trimester (n = 2), and the third trimester (n = 3). The fetal dose exposure from (18)F-FDG PET studies was estimated to range from 1.1 to 2.43 mGy for various trimesters in pregnancy (except for the patient in the early stage of pregnancy, in whom activity in the whole uterus was considered, and the fetal dose was estimated to be 9.04 mGy). All patients delivered healthy infants with no visible abnormalities at term. CONCLUSION The fetal radiation dose from (18)F-FDG PET studies is quite low and significantly below the threshold dose for deterministic effects due to radiation exposure to the fetus. The estimated fetal radiation exposure in our cases was slightly lower than existing estimates on fetal dose exposure, and as more data become available, the current fetal dose estimates may have to be modified accordingly. By addressing an important safety issue dealing with performing medically necessary (18)F-FDG PET in pregnant patients, these data are expected to help in the imaging workup of cancer patients during pregnancy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

A Prospective Study Comparing Functional Imaging (18F-FDG PET) Versus Anatomical Imaging (Contrast Enhanced CT) in Dosimetric Planning for Non-small Cell Lung Cancer.

 Objective(s): 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) is a well-used and established technique for lung cancer staging. Radiation therapy requires accurate target volume delineation, which is difficult in most cases due to coexisting atelectasis. The present study was performed to compare the 18F-FDG PET-CT with contrast enhanced computed tomogr...

متن کامل

Clinical Impact of 18F-FDG PET/CT on the Management of Gynecologic Cancers: One Center Experience

Objective(s): We aim to investigate the clinical impact of 18F-FDG PET/CT in managing patients with gynecological malignancies and pelvic or extrapelvic lymph nodes that are of equivocal significance on conventional imaging.Methods: We retrospectively evaluated 18F-FDG PET/CT scans of patients with gynecologic tumors who were referred to King Hussein Cancer Center from January 2010 to August 20...

متن کامل

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

The impact of 18F-FDG-PET-CT findings in the management of a patient with Mycosis Fungoides

In this case we report the detection of lymph node metastases in a 52 years old patient with mycosis fungoides utilising 18F- FDG-PET/CT which led to a change in the management of the patient.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 52 7  شماره 

صفحات  -

تاریخ انتشار 2011