Specific modeling and quantification of the aortic valve. Response.

نویسندگان

  • Ana García-Martín
  • Covadonga Fernández-Golfín
  • José Luis Zamorano-Gómez
چکیده

aortic annulus and the presence of dense calcium limit the applicability of two-dimensional imaging in estimating the annulus diameter for valve sizing. This has led to a great debate over the choice for measuring optimal diameter. However, this novel software determines the dimensions of the aortic annulus, including maximum and minimum diameter, perimeter, and cross-sectional area. Prospective studies are necessary to show the feasibility and the impact on transcatheter aortic valve implantation procedures. REFERENCES 1. García-Martín A, Ferná ndez-Golfín C, Zamorano-Gó mez JL. Nuevo modelo de cuantificació n aó rtica en pacientes pre-TAVI. factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicenter registry .specific modeling and quantification of the aortic and mitral valves from 4-D cardiac CT and TEE. quantitative 3-dimensional modeling of the aortic valve and root by 3-dimensional transesophageal echocardiography in normals, aortic regurgitation, and aortic stenosis: comparison to computed tomography in normals and clinical implications. of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. We appreciate the comments on our publication. 1 Although the purpose of our article was simply to introduce this new imaging software, we agree with these authors that the software provides additional information to that provided by aortic annulus assessment. As this author highlight, this information helps to improve our knowledge of cardiac structures and may contribute to more accurate preoperative assessment of patients undergoing trans-catheter aortic valve replacement and to avoiding potential complications. With this objective, other novel automated multi-detector computed tomography imaging software was applied in candidates for transcatheter aortic valve replacement; this novel software permitted reliable, reproducible and automated assessment of the aortic root dimensions and spatial relations with the surrounding structures. 2 In addition to the static measurements, aortic annulus tracking throughout the cardiac cycle can be analyzed with the software in order to assess its function and changes in distinct pathological conditions. Furthermore, this software can also be applied to the mitral valve and the aortic-mitral junction. With respect to the mitral valve, the annulus area and diameters, the intercommissural distance, and the length and height of the leaflets can be analyzed by this program and, as with the aortic valve, the mitral annulus can also be tracked throughout the cardiac cycle. Concerning mitro-aortic valvular physiology, the anatomic relationship between the 2 valves leads to synchronous and reciprocal behavior. In the last year, …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

Correlation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study

  Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 67 6  شماره 

صفحات  -

تاریخ انتشار 2014