Study on Fluorescent Detection Glucose Molecule Marked with ZnSe Nano Crystalline in Microchannels

نویسندگان

  • Zhong-chen Bai
  • Xin
چکیده

Shell-core structure of ZnSe nano crystalline cluster is used for marking glucose molecules in this paper. Fluorescent detection is successfully realized in microchannels. Mercaptoacetic acid is used for packing ZnSe nano crystalline cluster, which is dissolved in the water. Carboxyl of mercaptoacetic is used for connecting glucose molecule, and mixture solution of glucose molecule marked with ZnSe nano crystalline cluster is inleted by capillary force in muti-microchannels with diameter of 30 microns. Exciting light with the wavelength range from 265nm to 420nm is used for stimulating glucose molecules marked with ZnSe nano crystalline cluster in multimicrochannels, and fluorescent detection is carried out for glucose molecules. It is concluded that shell-core structure of ZnSe nano crystalline cluster is feasible for marking glucose molecules. The new method will lead to new application in many fields such as biologic analysis, biosensor, biologic detection and spaceflight, and so on.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optoelectronical Properties of a Metalloid-Doped B12N12 Nano-Cage

Abstract: The opteoelectronical properties of B12N12 nano-cage was investigated in thepresent of some metals by density functional theory (DFT). After the adsorption of atoxic molecule with all complexes, the electronic properties in B11GeN12 nano-cagewere significantly increased. The UV-Vis adsorption and Infrared spectroscopy ofcyanogen chloride over the B11GeN12 have ...

متن کامل

The design and development of fluorescent nano-optodes for in vivo glucose monitoring.

BACKGROUND The advent of fluorescent nanosensors has enabled intracellular monitoring of several physiological analytes, which was previously not possible with molecular dyes or other invasive techniques. We have extended the capability of these sensors to include the detection of small molecules with the development of glucose-sensitive nano-optodes. Herein, we discuss the design and developme...

متن کامل

Preconcentration of Mo(II) on Micro Crystalline Modified with Functionalized-Nano Graphene

A organic-solution-processable functionalized-graphene (SPFGraphene) material has been studied on pre-concentration and determination of trace Mo(II)ions. In this process, the effects of pH solution, elution conditions on pre-concentration of trace Mo(II) were studied and the effect of interfering ions was also investigated. A selective method for the fast determination of trace amounts of Mo (...

متن کامل

Preconcentration of Mo(II) on Micro Crystalline Modified with Functionalized-Nano Graphene

A organic-solution-processable functionalized-graphene (SPFGraphene) material has been studied on pre-concentration and determination of trace Mo(II)ions. In this process, the effects of pH solution, elution conditions on pre-concentration of trace Mo(II) were studied and the effect of interfering ions was also investigated. A selective method for the fast determination of trace amounts of Mo (...

متن کامل

Glucose-Sensitive Holographic (Bio)Sensors: Fundamentals and Applications

Nowadays sensors and especially biosensors play an important role in medical diagnosis and detection of food and environment contaminations. Biosensors’ facilities have been improved significantly by using technologies such as surface plasmon resonance, microfluidics, laser, and electrochemistry. These technologies are now available on chips in micro- and nano-scale and are capable of mea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008