Comparison of a fluorogenic anti-FXa assay with a central laboratory chromogenic anti-FXa assay for measuring LMWH activity in patient plasmas.
نویسندگان
چکیده
INTRODUCTION Low molecular weight heparins (LMWHs) are used worldwide for the treatment and prophylaxis of thromboembolic disorders. Routine laboratory tests are not required due to the predictable pharmacokinetics of LMWHs, with the exception of pregnant patients, children, patients with renal failure, morbid obesity, or advanced age. Anti-Factor Xa (anti-FXa) plasma levels are most often employed in the assessment and guidance of accurate dosing in these patient cohorts. MATERIALS AND METHODS A LMWH calibration curve was generated using citrated human pooled plasma spiked with pharmacologically relevant concentrations (0-1.2U/ml) of two low molecular weight heparins; enoxaparin and tinzaparin. Least squares analysis determined the best curve fit for this set of data which returned low sum of squares (SS) values for the log linear fit with an R(2) value of 0.98. 30 patient samples were tested in the fluorogenic assay and concentrations were determined using the log linear regression equation and correlated with a standard chromogenic assay used for heparin monitoring. RESULTS A statistically significant correlation was found between the fluorogenic and the chromogenic anti-FXa assays for 30 patient samples, with a slope of 0.829, offset of 0.258 and an R(2) value of 0.72 (p<0.0001). CONCLUSIONS In the study presented here, a fluorogenic anti-FXa assay was correlated with a standard laboratory chromogenic anti-FXa assay using samples from patients on LMWH therapy. Significant correlations between the values derived by the fluorogenic and chromogenic anti-FXa assays were found for the patient cohort tested in this study.
منابع مشابه
Comparison of the anticoagulant response of a novel fluorogenic anti-FXa assay with two commercial anti-FXa chromogenic assays.
INTRODUCTION Fast and accurate monitoring is crucial in the successful regulation of coagulation therapy. For the treatment of venous thromboembolism, both unfractionated heparin (UFH) and low molecular weight heparins (LMWHs) are commonly administered. The chromogenic anti-factor Xa (FXa) assay is currently considered the 'gold standard' assay for monitoring LMWH. However different commercial ...
متن کاملDevelopment of a fluorescent anti-factor Xa assay to monitor unfractionated and low molecular weight heparins.
Fluorogenic assays have many potential advantages over traditional clot-based and chromogenic assays such as the absence of interference from a range of factor deficiencies as well as offering the possibility of assays in platelet rich plasma or whole blood. A fluorogenic anti-factor Xa (anti-FXa) assay has been developed for the determination of unfractionated heparin (UFH), low molecular weig...
متن کاملMonitoring Low Molecular Weight Heparins at Therapeutic Levels: Dose-Responses of, and Correlations and Differences between aPTT, Anti-Factor Xa and Thrombin Generation Assays
BACKGROUND Low molecular weight heparins (LMWH's) are used to prevent and treat thrombosis. Tests for monitoring LMWH's include anti-factor Xa (anti-FXa), activated partial thromboplastin time (aPTT) and thrombin generation. Anti-FXa is the current gold standard despite LMWH's varying affinities for FXa and thrombin. AIM To examine the effects of two different LMWH's on the results of 4 diffe...
متن کاملDetermination of antithrombin-dependent factor Xa inhibitors by prothrombin-induced clotting time.
Prothrombinase-induced clotting time (PiCT) determines the anticoagulant effects of heparins, low molecular weight heparins (LMWHs), and direct thrombin inhibitors. At present, this is the only method that measures the effects of all of these inhibitors, in contrast to the prothrombin time, activated partial thromboplastin time (aPTT), Heptest, ecarin clotting time, and the chromogenic assays. ...
متن کاملQuantification of unfractionated heparin in human plasma and whole blood by means of novel fluorogenic anti-FXa assays.
Novel and sensitive plate-based fluorogenic anti-factor Xa (FXa) assays were investigated to quantify unfractionated heparin (UFH) in human plasma and whole blood within the therapeutic ranges of 0-1.6 U/mL and 0-0.8 U/mL, respectively. Two fluorogenic anti-FXa assay methods were defined for low (0-0.6 U/mL) and high (0.6-1.2 U/mL) pharmacologically relevant UFH concentration ranges in pooled h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thrombosis research
دوره 128 6 شماره
صفحات -
تاریخ انتشار 2011