Repair of thirty-six fractures in dogs using the Mennen clamp-on plate: preliminary results.

نویسندگان

  • W McCartney
  • C B Garvan
  • K Kiss
چکیده

OBJECTIVE To report the use of a human fixation device, the Mennen clamp-on plate (MCOP), for fracture repair in dogs as the sole method of fixation, or in combination with another fixation method such as an intramedullary pin. METHODS The study, which was performed to evaluate the use of the MCOP in fracture repair in dogs, included 36 cases that were selected between 2004 and 2008. The selected cases were all closed diaphyseal fractures, in which sufficient plate prongs could engage the bone on either side of the fracture. RESULTS Of the 36 cases, 32 had excellent outcomes, and four had complications; these were two cases of fixation failure, one case of osteomyelitis, and one with mild sciatic nerve deficits. DISCUSSION The MCOP is a promising method for fracture repair on its own for young puppies (six months or less), and in conjunction with other fixation methods in older dogs. It is quick to apply, as no screw holes are created and it achieved a successful outcome in 95% of the cases, provided the cases were appropriately selected for this method. CONCLUSIONS Using the MCOP has produced promising preliminary results in this study and warrants further evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mennen plate fixation for the treatment of periprosthetic femoral fractures.

BACKGROUND The management of periprosthetic femoral fractures after total hip and knee replacement remains difficult and controversial. This study was performed to determine the results of Mennen plate fixation for the treatment of periprosthetic femoral fractures. METHODS This retrospective multicenter study consists of a review of a consecutive series of thirty-five patients in whom a total...

متن کامل

Outcome of Repair of Distal Radial and Ulnar Fractures in Dogs Weighing 4 kg or Less Using a 1.5-mm Locking Adaption Plate or 2.0-mm Limited Contact Dynamic Compression Plate.

Objectives Retrospective evaluation of repairing distal radial and ulnar fractures in small breed dogs with the Synthes 1.5-mm locking Adaption plate system and compare results in a similar group of patients repaired with the Synthes 2.0-mm limited contact-dynamic compression plate (LC-DCP). Methods Electronic medical records from one specialty referral centre were reviewed from March 21, 2010,...

متن کامل

Impaction allografting revision for B3 periprosthetic femoral fractures using a Mennen plate to contain the graft: a technical report.

We prospectively evaluated the long-term results of a technique using the Mennen plate to contain impacted allograft and support cemented Exeter stem revision fixation for the treatment of three B3 periprosthetic femoral fractures (PFFs). Three patients with a median age of 77 years were followed-up for a median of 84 months. In all cases the stem bypassed the distal fracture line by a median l...

متن کامل

The use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation

Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...

متن کامل

Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate system.

OBJECTIVES To retrospectively evaluate stabilisation of long-bone fractures in cats and small dogs using the Unilock system. METHODS Medical histories and radiographs of consecutive patients with long-bone fractures stabilised with the Unilock system were reviewed. Cases with follow-up radiographs taken at least four weeks postoperatively were included. Signalment of the patient, fracture loc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Veterinary and comparative orthopaedics and traumatology : V.C.O.T

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 2009