Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes.
نویسندگان
چکیده
BACKGROUND Defibrillation may be improved if electrode configurations can be found that create a larger and more even voltage gradient field across the heart. This study determined the magnitude of the shock gradient fields generated by four nonthoracotomy electrode configurations for defibrillation. METHODS AND RESULTS In six dogs, a catheter was inserted containing a right ventricular apical electrode (V) and a right atrial electrode (A). A cutaneous patch electrode (P) was placed on the left lateral thorax. Shock potentials were recorded simultaneously from 128 electrodes in the left ventricular and right ventricular subepicardium and subendocardium, ventricular septum, and atria. With the chest closed, 50-mA shocks were given during diastole via the following lead configurations: V----A (V, cathode; A, anode); V----P; V----A+P; and V+A----P. Potential gradients were calculated at the subepicardium and subendocardium in millivolts per centimeter per volt of shock. In most dogs, the V----A+P configuration produced higher gradients throughout the ventricles than did V----A, V----P, or V+A----P. The maximum potential gradient was smaller for the V+A----P configuration than for V----A, V----P, or V----A+P. The gradient fields for the configurations with the catheter alone or combined with P were uneven. CONCLUSIONS It is possible to estimate shock gradient fields in three dimensions. Of the four configurations tested, V----A+P produced the highest gradients and V+A----P produced the lowest high gradient. The gradient fields were uneven throughout the ventricles.
منابع مشابه
Comparison of defibrillation probability of success curves for an endocardial lead configuration with and without an inactive epicardial patch.
OBJECTIVES This study sought to assess the effect of passive "bystander" epicardial electrodes on defibrillation efficacy. BACKGROUND We hypothesized that an inactive epicardial patch placed in an area of low potential gradient from an endocardial electrode shock might affect defibrillation efficacy through its effects on the shock field and the underlying potential gradient. METHODS We stu...
متن کاملIntracardiac Echocardiography during Catheter-Based Ablation of Atrial Fibrillation
Accurate delineation of the variable left atrial anatomy is of utmost importance during anatomically based ablation procedures for atrial fibrillation targeting the pulmonary veins and possibly other structures of the atria. Intracardiac echocardiography allows real-time visualisation of the left atrium and adjacent structures and thus facilitates precise guidance of catheter-based ablation of ...
متن کاملFeasibility study for real time three dimensional Doppler intracardiac echocardiography.
Using catheter-mounted two-dimensional array transducers, we have obtained real-time three-dimensional color flow and spectral Doppler ultrasound images in phantoms. We have constructed several transducers operating at 5 MHz with up to 137 channels inside a 12 French catheter lumen. The transducer configuration may be side scanning or beveled with respect to the long axis of the catheter lumen....
متن کاملLocaLisa: new technique for real-time 3-dimensional localization of regular intracardiac electrodes.
BACKGROUND Estimation of the 3-dimensional (3D) position of ablation electrodes from fluoroscopic images is inadequate if a systematic lesion pattern is required in the treatment of complex arrhythmogenic substrates. METHODS AND RESULTS We developed a new technique for online 3D localization of intracardiac electrodes. Regular catheter electrodes are used as sensors for a high-frequency trans...
متن کاملIntracardiac Infection at the Tip of Hemodialysis Catheter: Life threatening Morbidity
Endocarditis and intracardiac infection have been increased recently especially in dialysis dependent renal failure patients. This is usually intractable infection to broad spectrum Antibiotic therapy and in most cases surgical intervention was necessary. We have presented 45 years old man with intracardiac infection at the tip of dialysis catheter that after catheter removal intracardiac infec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 85 5 شماره
صفحات -
تاریخ انتشار 1992