"Spin-echo Like T1 Contrast" Volumetric Black-Blood Images Using 3D LOWRAT: Low Refocusing Flip Angle TSE

نویسندگان

  • M. Yoneyama
  • M. Nakamura
  • T. Tabuchi
  • A. Takemura
  • J. Ogura
چکیده

Introduction: T1 contrast is typically acquired using multi-slice two-dimensional spin-echo (2D SE), inversion recovery fast spin echo (T1 fluid-attenuated inversion recovery : T1FLAIR) or 3D T1-weighted spoiled gradient-echo (3D T1TFE) imaging [1]. However, these conventional methods have problems when used for contrast enhancement studies. 2D-SE requires long scan time for 3-plane diagnosis, resulting in ghosting flow artifacts. T1FLAIR has a low sensitivity to contrast agents. 3D T1TFE captures high signals from small vessels. As a solution to these problems, 3D variable refocusing flip angle turbo spin echo (3D VRFA-TSE) imaging is used recently [2,3]. 3D VRFA-TSE decreases flow artifacts by sequence-endogenous flow-void enhancement. However, 3D VRFA-TSE does not bring good T1 contrast due to long echo train and pseudo steady-state effects, thus 3D VRFA-TSE was originally used to acquire T2 contrast [4]. In this study, we propose a new scheme of “T1-optimized” black-blood 3D TSE pulse sequence with low refocusing flip angles. Methods: Volunteer experiments were acquired by 3D VISTA (Volume ISotropic TSE Acquisition) with refocusing flip angle control (LOW Refocusing flip Angle VISTA: LOWRAT) using a 3.0 Tesla (T) whole-body clinical imager (Achieva, Philips Medical Systems, Best, the Netherlands). We evaluated two areas; contrast optimization and comparison. a) Contrast optimization: We performed this on six subjects. All data were acquired by 3D LOWRAT to assess the effect of T1 contrast. The examined imaging parameters were: 1) refocusing flip angles , 2) Pseudo steady-state preparation (Ninety-Plus-Half-Alpha: NPHA preparation (90 ̊excitation-"90+α/2"-α-α-α-α-) [5], and asymptotic preparation (90 ̊excitation-α1-α2-α3-α4-α-α-) [6], 3) excitation flip angles , 4) echo train length (ETL), 5) effective TE / startup echoes (best echo number for the center of K-space), and 6) TR. b) Contrast comparison: The conventional T1W 2D SE sequence was performed with the same FOV, slice locations and acquisition matrix as 3D LOWRAT. Acquisition parameters for T1W 2D SE were TR/TE=500/10ms, FA=80°. CNR measurements between grey matter and white matter (GMWM), and grey matter and CSF (GM-CSF) were used to compare 2D SE and optimized 3DLOWRAT. CNR measurements were performed at the same anatomical location for 2D SE and 3D LOWRAT. Results and Discussion: a) The optimal parameter for T1-optimized black-blood imaging was 1) low refocusing flip angles (recommend the 30-50°) to increase flow-void effect (decreasing flow artifacts in post contrastenhanced) and to decrease image blurring [Fig.1] , 2) choose NPHA pseudo steady-state preparation to decrease T2 relaxation effect and magnetization transfer (MT) effect [Fig.2] ,3) low excitation flip angles (recommend the 60-75°) to decrease MT effect [7] [Fig.3] , 4) short ETL (recommend 15-20) to decrease T2 relaxation effect and MT effect [Fig.4] , 5) best echo number for the center of K-space was the 2nd echo (effective TE was 2x echo-spacing), and 6) shortest TR (recommend 350-400ms) to save scan duration. b) Based on these results, we used optimized parameters for T1W contrast comparison with 2D SE. Contrast behavior of 3D LOWRAT T1W was similar to that of 2D SE. Fig.5 shows the preand postcontrast enhanced 1mm isotropic T1-weighted black-blood images by "optimized" 3D LOWRAT sequences. Imaging parameters were: 3D VISTA, sagittal plane, FOV=256mm, matrix=256x256, slices=224, slice thickness=1mm (no slice ZIP), 2D SENSE (Phase reduction=2.0, Slice reduction=1.6), TR=400ms, TE=9.2ms (echo-spacing=4.6ms), excitation FA=65°, refocusing FA=40°, NPHA pseudo steadystate preparation, ETL=16. Total scan duration was 5:37. Conclusion: This study showed the new scheme of “T1-optimized” blackblood 3D TSE pulse sequence with low refocusing flip angles. This optimal sequences can be used for 3D volumetric T1 weighted black-blood imaging. And may also be used for detecting brain metastasis, and potentially plaque characterization in vessel wall imaging. Further investigation is needed for clinical evaluation and limitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of T1 contrast in whole-brain black-blood imaging using motion-sensitized driven-equilibrium prepared 3D turbo spin echo (3D MSDE-TSE).

We demonstrated a new scheme for performing the T1-enhanced whole-brain black-blood imaging pulse sequence using motion-sensitized driven-equilibrium prepared 3-dimensional (3D) turbo spin echo (MSDE-TSE) with anti-driven-equilibrium post pulse. The use of an anti-driven-equilibrium pulse considerably improved the T1 contrast of MSDE-TSE black-blood images. This sequence can be used for whole-b...

متن کامل

Accuracy of postcontrast 3D turbo spin-echo MR sequence for the detection of enhanced inflammatory lesions in patients with multiple sclerosis.

BACKGROUND AND PURPOSE Therapeutic strategies for patients with MS partly rely on contrast-enhanced MR imaging. Our aim was to assess the diagnostic performance of 3D turbo spin-echo MR imaging with variable refocusing flip angles at 3T for the detection of enhanced inflammatory lesions in patients with multiple sclerosis. MATERIALS AND METHODS Fifty-six patients with MS were prospectively in...

متن کامل

Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS).

A variation of the rapid acquisition with relaxation enhancement (RARE) sequence (also called turbo spin-echo (TSE) or fast spin-echo (FSE)) is presented. This technique uses variable flip angles along the echo train such that magnetization is initially prepared into the static pseudo steady state (PSS) for a low refocusing flip angle (alpha < 180 degrees ). It is shown that after such a prepar...

متن کامل

Simultaneous spin-echo refocusing.

A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from different slices can occur. A novel periodic gradient spoiler scheme eliminat...

متن کامل

Comparative Evaluations of 3d Turbo Spin Echo (tse) Motion Sensitized Driven Equilibrium (msde) and 2d Double Inversion Recovery Tse Sequences for T1-weighted Black-blood Carotid Atherosclerosis Imaging

Introduction In vivo MR carotid plaque imaging has been used to identify vessel morphology and plaque characteristics, and their associations with clinical symptoms. [1] Two-dimensional T1 weighted (T1W) double inversion recovery spin echo [2] and subsequently quadruple inversion recovery spin echo sequences [3] have been used to obtain the contrast between vessel wall and lumen, and identify c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009