A preliminary evaluation of a reusable digital sterilization indicator prototype.

نویسندگان

  • R Puttaiah
  • J Griggs
  • M D'Onofrio
چکیده

BACKGROUND Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of sterilizers. Data loggers or independent digital parametric indicators are innovative devices that provide more information than various classes chemical indicators. In this study we evaluated a prototype of an independent digital parametric indicator's use in autoclaves. AIM The purpose of this study was to evaluate the performance of an independent digital indicator/data logger prototype (DS1922F) that could be used for multiple cycles within an autoclave.MG Materials and methods: Three batches of the DS1922F (150 samples) were used in this study that was conducted in a series. The first batch was challenged with 300 sterilization cycles within an autoclave and the data loggers evaluated to study failures and the reason for failure, make corrections and improve the prototype design. After changes made based on studying the first batch, the second batch of the prototype (150 samples) were challenged once again with 300 sterilization cycles within an autoclave and failure studied again in further improvement of the prototype. The final batch (3rd batch) of the prototype (150 samples) was challenged again but with 600 cycles to see how long they would last. Kaplan-Meier survival analysis analyses of all three batches was conducted (α = 0.05) and failed samples qualitatively studied in understanding the variables involved in the failure of the prototype, and in improving quality. RESULTS Each tested batch provided crucial information on device failure and helped in improvement of the prototype. Mean lifetime survival of the final batch (Batch 3) of prototype was 498 (480, 516) sterilization cycles in an autoclave. CONCLUSION In this study, the final batch of the DS1922F prototype data logger was found to be robust in withstanding the challenge of 600 autoclave cycles, with a mean lifetime of more than 450 cycles, multiple times more than prescribed number of cycles. CLINICAL SIGNIFICANCE Instrument reprocessing is among the important aspects of infection control. While stringent procedures are followed in instrument reprocessing within the clinic in assuring patient safety, regular use of sterilization process indicators and periodic biological validation of the sterilizer's performance is necessary. Chemical indicators for use in Autoclaves provide information on whether the particular cycle's parameters were achieved but do not provide at what specific point in time or temperature the failure occurred. Data loggers and associated reader software as the tested prototype in this evaluation (DS1922F), are designed to provide continuous information on time and temperature of the prescribed cycle. Data loggers provide immediate information on the process as opposed to Biological Indicators that take from days to a week in obtaining a confirmatory result. Further, many countries do not have the sterilization monitoring service infrastructure to meet the demands of the end users. In the absence of sterilization monitoring services, use of digital data loggers for each sterilization cycle is more pragmatic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in the light intensity of the fiberoptic laryngoscope blade by steam sterilization.

BACKGROUND I investigated the effects of steam sterilization on light intensity of reusable fiberoptic laryngoscope blades. METHODS Six new reusable fiberoptic Macintosh laryngoscope blades were steam sterilized. The light intensity was measured, the tip of the blades was photographed, and the light intensity of six new plastic disposable Macintosh laryngoscope blades was also measured. RES...

متن کامل

Evaluation of single-use reprocessed laparoscopic instrument sterilization.

This experimental, comparative, laboratory study evaluated the effectiveness of the sterilization of single-use laparoscopic instruments--SULIs (grasper, dissector, scissors, Veress needle and electrosurgical probe system), after contamination-challenge with bacterial spores and sheep blood, and compared the results of the sterilization tests with those of the equivalent reusable instruments. T...

متن کامل

Evaluating the Usability and Efficiency of the National Oil Corporation - Digital Library in Libya

This paper presents a preliminary discussion on some of the results from a survey aimed to explore, describe and explain some of the usability characteristics in digital library evaluation in the Libyan context. The study is framed in the evaluation of a bilingual digital library: The National Oil Corporation (NOC) Digital Library in Libya. It is worth mentioning in this context that this study...

متن کامل

Immunohistochemical Evaluation of Human p53 Tumor Suppressor Protein Content in Ductal Carcinoma in Situ of the Breast

The focus of this study was to determine if early detection of mutant p53 accumulation may be an early indicator of tumor aggressiveness and transformation to invasive breast cancer. For this purpose, the p53 content of 100 human breast biopsies classified as ductal carcinoma (DCIS), was evaluated by immunohistochemical method. All specimens were microscopically classified into histologic types...

متن کامل

Reusable and Usable Environment for the Digital Courseware Domain

This paper considers a functional framework that creates a usable authoring support environment (ASE) for digital course design, and outputs reusable components. Within the context of considering the courseware domain as a domain of interactive software systems, we developed an ASE prototype. The objectives of this prototype include the provision of a usable authoring tool to develop interactiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 15 5  شماره 

صفحات  -

تاریخ انتشار 2014