Reducing the Gaussian Blur Artifact from Ct Medical Images by Employing a Combination of Sharpening Filters and Iterative Deblurring Algorithms

نویسنده

  • GHAZALI SULONG
چکیده

Obtained images through imaging systems are considered as degraded versions of the original view. Computed Tomography (CT) images have different types of degradations such as noise, blur and contrast imperfections. This paper handles the issue of deblurring CT medical images affected by Gaussian blur. Image deblurring is the procedure of decreasing the blur amount and grant the filtered image with an overall sharpened form. In this paper, the authors considered the Laplacian sharpening filter and the iterative Richardson – Lucy algorithm, and implemented a mixture of these two techniques to process the CT medical images. The suggested technique is applied to medical images that are synthetically and naturally degraded by blur. Moreover, an evaluation between the proposed combination and each employed technique is provided, along with the accuracy calculation using the universal image quality index (UIQI).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Biomedical Image Denoising Based on Hybrid Optimization Algorithm and Sequential Filters

Background: Nowadays, image de-noising plays a very important role in medical analysis applications and pre-processing step. Many filters were designed for image processing, assuming a specific noise distribution, so the images which are acquired by different medical imaging modalities must be out of the noise. Objectives: This study has focused on the sequence filters which are selected ...

متن کامل

Performance Comparison of Gaussian and Elliptic High Pass Filter

In this paper, Gaussian and elliptic high pass filters are analyzed for image sharpening qualitatively and quantatively . The filters are implemented in frequency domain using matlab software. Experiments are performed to compare the performance of both the filters ,processed images are presented. The results demonstrate that elliptic yields better results.

متن کامل

Performance Comparison of Gaussian and Elliptic High Pass Filter

In this paper, Gaussian and elliptic high pass filters are analyzed for image sharpening qualitatively and quantatively . The filters are implemented in frequency domain using matlab software. Experiments are performed to compare the performance of both the filters ,processed images are presented. The results demonstrate that elliptic yields better results.

متن کامل

Efficient Deblurring by Iterative Reconstruction for Spiral-in-out Imaging

H. Guo, Q. Zhu, T. B. Harshbarger, A. W. Song Department of Biomedical Engineering, Duke University, Durham, NC, United States, Brain Imaging and Analysis Center at Duke University, Durham, NC, United States, Electrical and Computer Engineering, Duke University, Durham, NC, United States Introduction To address the signal loss due to the susceptibility differences at the air/tissue interfaces, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012